Green motion PIPISTREL SKYCHARGE MOBILE Technical Documentation Manual

Green motion PIPISTREL SKYCHARGE MOBILE Technical Documentation Manual

Hide thumbs Also See for PIPISTREL SKYCHARGE MOBILE:

Advertisement

Quick Links

SKYCHARGE MOBILE
POWERED BY GREEN MOTION AND PIPISTREL
TECHNICAL DOCUMENTATION
NON-CONTRACTUAL PICTURES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PIPISTREL SKYCHARGE MOBILE and is the answer not in the manual?

Questions and answers

Summary of Contents for Green motion PIPISTREL SKYCHARGE MOBILE

  • Page 1 SKYCHARGE MOBILE POWERED BY GREEN MOTION AND PIPISTREL TECHNICAL DOCUMENTATION NON-CONTRACTUAL PICTURES...
  • Page 2: Table Of Contents

    SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 2 Table of content 1 INTRODUCTION Technical Specifications Dimensions and weights 2 CONNECTION TO THE GRID 3 COMMISSIONING Opening the SKYCHARGE Mobile casing Changing the charging current eMobility Cockpit connection 4 USAGE OF THE STATION Description of the trolley Description of the station Charging states...
  • Page 3: Introduction

    SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 3 1 INTRODUCTION 1.1 Technical Specifications POWER INPUT DC SKYCHARGE MOBILE CHARGER Input voltage 3 x 400 V 50 Hz 3 x 32 A (22 kW) Input current Electrical Grid Connection Plug CEE 32 A, 5 poles 400 V, 6h Power factor >...
  • Page 4: Connection To The Grid

    Please be sure to install a mandatory RCD device after the C40 breaker. Green Motion strongly recommends using a Doepke RCCB DFS 4 040-4/0.03-A EV R as an RCD device or Eaton 167897 FRCDM-40/4/03-G/B. NOTE FOR SWITZERLAND...
  • Page 5 SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 5 Circuit diagram Connection Diagram: Figure 1: GB/T 18487.1-2015 Schematic Diagram of DC Charging - Extracted from AS6968 Rev.A Figure 2: GB/T 20234.3-2015 DC Charging Plug - Extracted from AS6968 Rev.A...
  • Page 6: Commissioning

    SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 6 3 COMMISSIONING The opening of the charger as well as any configuration changes must be carried out by a qualified electrician according to the local safety and electrical regulations and laws. Failure to comply with the regulations in this manual will result in the end the warranty period.
  • Page 7: Changing The Charging Current

    SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 7 3.2 Changing the charging current Electric shock hazard! Please make sure that the main power supply is turned off before trying to connect the power to the charging station. In any case, working under voltage shall be avoided. The electrical cable must reach the terminal from the left.
  • Page 8: Emobility Cockpit Connection

    The SKYCHARGE Mobile implement’s a 3G/4G/LAN router to enable the IoT connection. The router is located on the SKYCHARGE Mobile door. Router Configuration The configuration is performed on the Green Motion Manufacturing Plan Teltonika RUTX09 modem router configuration Default settings: - IP: 192.168.1.1...
  • Page 9 Authorize the management of the router from the WAN (Only if in a private network) ▪ Go to System> Administration> Access control ● Check Enable Remote HTTP and Enable Remote HTTPS (*) Please contact Green Motion SA support for the password...
  • Page 10: Usage Of The Station

    SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 10 4 USAGE OF THE STATION 4.1 Description of the trolley 1. Cable holder 2. Ø125 mm wheel with brake system 3. Ø125 mm wheel 4.2 Description of the station 1. Button indicator 2. Touch screen display 3.
  • Page 11: Charging States

    SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 11 4.3 Charging states Button indicator Button Status display Comments No light Not powered or start-up stage Green light on Ready to be use or need user interaction Charge initialization, vehicle charging, or charge Blue light on finished Red light on...
  • Page 12 SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 12 LED display The LED display indicates the charging status. 100% LED Display Status display Comments Green light on Ready to be use Flashing green light Start-up stage Breathing green light Waiting for user interaction Flashing blue light Charge start-up stage Breathing blue light...
  • Page 13 SKYCHARGE Mobile – TECHNICAL DOCUMENTATION Page 13 Touch screen display As the touch screen display is the user interface and implements a lot of screen, please take time to read what is described and write on the screen before to operate. In this section you will find the information to start your experience.
  • Page 14: Maintenance

    Page 14 MAINTENANCE In order to prevent any technical failure, Green Motion is performing maintenance services. Please contact Green Motion Support for more information on maintenance contracts. Electric shock hazard! Please make sure that the main power supply is turned off before trying to open the charging station.
  • Page 15: Cleaning Or Replacing The Filters

    ISO COARSE 50% / G4 DIM. 161 X 397 MM 5.3 Support Green Motion telephone support is available Monday to Friday from 08:00 to 12:00 and from 13:00 to 17:00 (16:00 on Friday) CET Email: support@greenmotion.ch Tel: +41 21 544 04 46...