bolid S2000-IK Rev.03 Instruction Manual

Addressable volumetric pir motion detector

Advertisement

Quick Links

S2000-IK Rev.03
Addressable Volumetric PIR Motion Detector

GENERAL

S2000-IK Revision 03 Addressable Volumetric Passive Infrared (PIR) Motion Detector (hereinafter referred to as the
detector) is designed to be used indoors. It detects intrusion into protected areas and sends an alarm message to the
connected S2000-KDL controller via the two-wire multiplex addressable polling loop.
The S2000-IK rev.03 supports DPLS_v2.xx protocol.
The detector features:
A red LED to indicate detector's operability
Programming the address and communicating data with the connected S2000-KDL
A tamper switch to provide detection of unauthorized access as well as to adjust the detector
The detector is intended for round-the-clock operation.

SPECIFICATIONS

Input Voltage (via the polling loop of an S2000-KDL)
Current Consumption (via the loop of the S2000-KDL)
Pre-Operation Time
Detection Range
Target Speed
White Light Immunity
Sabotage-Resistant Zone
Operating Temperatures
Humidity
Overall Dimensions (H x W x D)
Weight

STANDARD DELIVERY

Find the following unpacking the S2000-IK rev.03:
S2000-IK rev.03 detector
This Instruction Manual
Two woodscrews 3.5×30
Two wall plugs 6×30
Two tapping screws 2.2×6.5
Bracket (to be ordered separately)
Package

MOUNTING LOCATION CONSIDERATIONS

The detector is intended to be used indoors. Considering a location to mount the detector, please take into account the
following:
1. Do not locate the detector above heaters, radiators, etc. or close to vent openings.
2. Do not locate the detector in places where it can be exposed to direct sun rays.
3. In capital facilities the detector should be mounted on a wall or in a corner.
4. Within light metal structures the detector should be mounted on structural frames (columns, trusses) rather than on
a wall or a corner.
5. To avoid condensation on the lens and case of the detector, do not attach the detector just over the entrance
opening.
6. There should not be any waving things like curtains and incandescent lamps in the detection area.
INSTRUCTION MANUAL
8 ÷ 10 VDC
0.65 mA max when indication is off
15 s max
0.3 m to 12 m
0.3 m/s to 3 m/s
Better than 6500 Lux
Yes
−30 to +50° C
Up to 95% at 25° C, non-condensing
68 mm × 93mm × 41 mm max
125 gram max

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S2000-IK Rev.03 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for bolid S2000-IK Rev.03

  • Page 1 68 mm × 93mm × 41 mm max Overall Dimensions (H x W x D) Weight 125 gram max STANDARD DELIVERY Find the following unpacking the S2000-IK rev.03: S2000-IK rev.03 detector This Instruction Manual Two woodscrews 3.5×30 Two wall plugs 6×30 Two tapping screws 2.2×6.5...
  • Page 2 The S2000-IK rev.03 to operate properly within two-wire addressable polling loop of the S2000-KDL controller, it must be assigned to a unique number in the range of 1 to 127 within the loop – the address which is stored in the S2000-IK rev.03 non-volatile memory (EEPROM).
  • Page 3 The Tamper Restored message will be issued to the network controller in 15 seconds since closing the case. DETECTION PATTERN Figure 2: S2000-IK Rev.03 Detection Pattern...
  • Page 4 BOLID ONE YEAR LIMITED WARRANTY Bolid Company and its divisions and subsidiaries («Seller»), 4 Pionerskaya Str., Korolev 141070, Moscow Region, Russia warrants its security equipment (the «product») to be free from defects in materials and workmanship for one year from date of original purchase, under normal use and service.