GENERAL

S2000-IK Revision 02 Addressable Volumetric Passive Infrared (PIR) Motion Detector (hereinafter referred to as the
detector) is designed to detect intrusion into the protected premises with sending alarms to the connected polling loop
controller S2000-KDL or S2000-KDL-2I via its two-wire multiplex addressable polling loop (PL).
The detector is intended to operate as a part of an Orion fire and intrusion alarm system.
The detector features volumetric detection zone providing pet immunity for animals up to 20 kg.
The detector is immune against lighting and radio frequency interference.

KEY FEATURES

Dual-element pyro-electric infrared sensor
High-density coverage offering high probability of detecting an intruder
Protected against insects entering to the pyro-electric infrared sensors
Sabotage-resistant zones just beneath the detector prevents unauthorized access to the detector
Digital signal processing
Powered via the multiplex addressable polling loop of a PL controller
Supports DPLS_v2.51 protocol

SPECIFICATIONS

Detection Zone
Detection Range
Input Voltage
Consumed Current
Horizontal Field-of-View
Operating Temperatures
Relative Humidity
Ingress Protection Rating
Overall Dimensions (H x W x D)
Weight
Mounting Height

MOUNTING LOCATION CONSIDERATIONS

The detector is intended to be used indoors. Considering a
location to mount the detector, please take into account that the
detection zone must not be obscured by any non-transparent
objects such as curtains, houseplants, cabinets, room dividers,
etc. as well as by glass or mesh partitions.
Do not locate the detector where it can be exposed to false alarm
sources such as windows, air conditioners, heaters, radiators, etc.
Wires of the multiplex addressable polling loop should be located
away from high-voltage electric cables.
The detector allows wall or corner mounting at a height of 2.3 m
above the floor. This provides the detection range at least 10
meters. The detection pattern is shown in Figure 1.
Volumetric (see Figure 1)
10 m
From the PL controller
0.5 mA max w/o indication
90°
−30 to +50° C
95% at 25° C, non-condensing
IP41
105 mm × 75 mm × 56 mm max
0.1 kg max
2.3 meters
Figure 1: S2000-IK Rev.02 Detection Pattern

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S2000-IK and is the answer not in the manual?

Questions and answers

Summary of Contents for bolid S2000-IK

  • Page 1 OPERATING AND INSTALLATION MANUAL GENERAL S2000-IK Revision 02 Addressable Volumetric Passive Infrared (PIR) Motion Detector (hereinafter referred to as the detector) is designed to detect intrusion into the protected premises with sending alarms to the connected polling loop controller S2000-KDL or S2000-KDL-2I via its two-wire multiplex addressable polling loop (PL).
  • Page 2 S2000-KDL. Figure 5 shows the wiring diagram for connecting RS-485A the detector to the multiplex addressable polling RS-485B S2000-IK loop of the S2000-KDL controller which is in turns +12 V connected to the network controller and the power supply.
  • Page 3 PC using the UProg Configuration Tool. The parameter Device Indication Control of the S2000-KDL polling loop input zone which is assigned to the S2000-IK rev.02 should be set to a proper value. The value can be 0 (indication is inhibited), 1 (local indication), or 2 (indication controlled remotely by the PL controller).

Table of Contents