NetPing 995S2 User Manual

Supply voltage sensor
Hide thumbs Also See for 995S2:

Advertisement

Quick Links

1. [ENG] NetPing Supply Voltage Sensor 995S2, User guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.1 [ENG] [995S2] Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 [ENG] [995S2] Disclaimer and Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 [ENG] [995S2] Overview and Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5 [ENG] [995S2] Installation and Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.6 [ENG] [995S2] Shipping Kit of the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.7 [ENG] [995S2] Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.8 [ENG] [995S2] Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.9 [ENG] [995S2] Operating and storage conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
1.10 [ENG] [995S2] Additional Documents and Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Advertisement

Table of Contents
loading

Summary of Contents for NetPing 995S2

  • Page 1: Table Of Contents

    1. [ENG] NetPing Supply Voltage Sensor 995S2, User guide ....... .
  • Page 2: Eng] Netping Supply Voltage Sensor 995S2, User Guide

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] NetPing Supply Voltage Sensor 995S2, User guide Copyright © NetPing east Co., Ltd / E-mail: support@netpingdevice.com www.netpingdevice.com / Phone: +886-2-23121582...
  • Page 3: Eng] [995S2] Introduction

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Introduction This guide will help you to get to know  the features of the NetPing Supply Voltage Sensor 995S2 , get an idea of its functionality and technical specifications, and prepare the device for operation.
  • Page 4: Eng] [995S2] Disclaimer And Copyright

    User Guide, as well as firmware and software of devices and this User Guide belong to NetPing global Ltd. Сopying, replication and translation of this user guide to other languages are not allowed without a prior written permission of a rightholder.
  • Page 5: Eng] [995S2] Overview And Key Features

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Overview and Key Features The physical configuration of the device is shown in the photo: Bottom view: View from above: Copyright © NetPing east Co., Ltd / E-mail: support@netpingdevice.com www.netpingdevice.com...
  • Page 6 NetPing server room environmental monitoring solutions and IP power distribution units. Device specifications Meaning Threshold r esponse (valid only for 995S2   modification 178–193 V intended for 220 V network) Threshold release (valid only for 995S2   modification,  inte 155 175 V –...
  • Page 7: Eng] [995S2] Connectors And Indication Elements

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Connectors and Indication Elements View from above The sensor operation indicator is on when it is connected to the power supply.  Side view Copyright © NetPing east Co., Ltd / E-mail: support@netpingdevice.com www.netpingdevice.com...
  • Page 8 NetPing server room environmental monitoring solutions and IP power distribution units. The type of output contacts Copyright © NetPing east Co., Ltd / E-mail: support@netpingdevice.com www.netpingdevice.com / Phone: +886-2-23121582...
  • Page 9 NetPing server room environmental monitoring solutions and IP power distribution units. N.O.-C pair - normally opened contacts. Opened when voltage failure is detected. N.C.-C pair - normally closed contacts. Closed when registering a lack of voltage. Copyright © NetPing east Co., Ltd / E-mail: support@netpingdevice.com www.netpingdevice.com...
  • Page 10: Eng] [995S2] Installation And Connection

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Installation and Connection The supply voltage sensor can be installed on a horizontal or vertical surface. Mounting holes are not provided. When you install the device, the following restrictions must be considered: Do not expose the device to direct sunlight.
  • Page 11 Sensor Connection Diagrams The sensor output is a dry contact. The connection order of the N-NC or N-NO wires is not important. NetPing 2/PWR-220 v3/ETH, NetPing 2 IP PDU ETH 53R14, NetPing 2 IP PDU GSM3G 203R15 NetPing 2/PWR-220 v3/ETH  —...
  • Page 12 NetPing server room environmental monitoring solutions and IP power distribution units. Sensor Loop Device Terminal Black (common) Red (N.C.) I 1...4 White (N.O.) I 1...4 UniPing server solution v3, UniPing server solution v4/SMS UniPing server solution v3  — http://www.netpingdevice.com/products/uniping-server-solution-v3 UniPing server solution v4/SMS  —...
  • Page 13 NetPing server room environmental monitoring solutions and IP power distribution units. Белый (N.O.) IO 1...8 NetPing IO v2 NetPing IO v2  — http://www.netpingdevice.com/products/netping-io-v2 Sensor Loop Device Terminal Black (common) Red (N.C.) IO 1...4 White (N.O.) IO 1...4 NetPing 8/PWR-220 v4/SMS NetPing 8/PWR-220 v4/SMS —...
  • Page 14 NetPing server room environmental monitoring solutions and IP power distribution units. Sensor Loop Device Terminal Black (common) Red (N.C.) 1...4 White (N.O.) 1...4 Copyright © NetPing east Co., Ltd / E-mail: support@netpingdevice.com www.netpingdevice.com / Phone: +886-2-23121582...
  • Page 15: Eng] [995S2] Shipping Kit Of The Device

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Shipping Kit of the Device This shipping kit includes: NetPing Supply Voltage Sensor 995S2 with the soldered wire of 1.5 meters long — 1 pc.; Quick Start Guide — 1 pc.;...
  • Page 16: Eng] [995S2] Warranty

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Warranty The manufacturer guarantees normal operation of the product within 24 months from the date specified on the warranty sticker if a buyer follows operating and storage conditions. Manufacturer warranty applies only to failure of a device which occurred because of defects in manufacturing process of products and components used.
  • Page 17: Eng] [995S2] Safety Precautions

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Safety Precautions The next information will allow users to avoid both injuries and damaging a device as well as connected equipment. The device should only be used on the power supply specified by the manufacturer. Use of any other type of power may damage the product.
  • Page 18: Eng] [995S2] Operating And Storage Conditions

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Operating and storage conditions This sensor is designed for continuous round-the-clock operation indoors. The sensor is resistant to air temperature from -30 °С to +50 °С (without moisture condensation, at normal humidity) under operating conditions. The sensor should be protected from the impact of moisture and direct sunlight.
  • Page 19: Eng] [995S2] Additional Documents And Links

    NetPing server room environmental monitoring solutions and IP power distribution units. [ENG] [995S2] Additional Documents and Links The page of the device 995S2: http://www.netpingdevice.com/products/voltage-sensor-995s2 Manufacturer's website: http://www.netpingdevice.com Technical support contacts: http://www.netpingdevice.com/support Phone: +886-2-23121582 E-mail: support@netpingdevice.com Copyright © NetPing east Co., Ltd / E-mail: support@netpingdevice.com www.netpingdevice.com...

Table of Contents