Adjustment Of External Augers Running Time; Adjusting Of Maintenance Time - Janfire Flex-a Installation And Service

Pellet burner
Table of Contents

Advertisement

For example, if the feeding time should be 1.1 sec then diodes for elspiral and mikrobrytare shine.
See other settings shown in the following figure. Feeding time can be adjusted between 0.6 and 1.4
sec.
Press STOPP to save the new setting.
Edit button
¤

3.6 Adjustment of external augers running time

Press edit button from feeding settings mode to activate external augers settings mode.
Time is normally 2 min.
Only alarm diode at the bottom "extern motor" shine.
One press to "Dos" increase time for 1 min and turn on one diode more.
One press to "Ext" decrease time for 1 min and turns out one diode.
For example, if the external augers running time should be 4 min then the three bottom diodes
(extern motor, flamvakt and elspiral) should shine.
Termokontakt = 6 min
Mikrobrytare = 5 min
Elspiral
= 4 min
Flamvakt
= 3 min
Extern
= 2 min
Press "Stop" to save the new setting.

3.7 Adjusting of maintenance time

Press Edit from external auger settings mode to activate mode for adjusting of maintenance time.
Maintenance time is normally 60 min."Termokontakt" diode at the top shine.
IA Brännare Flex-a R2 SV
¤
¤
¤
¤
0,8
0,7
¤
0,6
¤
¤
1,2
1,1
¤
¤
1,0
0,9
© Janfire 2009
Installationsanvisning Janfire Flex - a
¤
¤
1,4
1,3
¤
)
14(19