Control Panel - Janfire Flex-a Installation And Service

Pellet burner
Table of Contents

Advertisement

3.2 Control panel

Functional description of the control unit. Explanation of the light signals and burning status
Note: Work with electrical parts of the plant should only be performed after the main fuse has disconnected,
and only by qualified personal
Buttons
STOPP = stopp/stand by
4 = 18 kW power
3 = 15 kW power
2 = 12 kW power
1 = 9 kW power
M = Manuell operation (15 kW)
Note !!! Ext Dos buttons can only
be activaded in Stop Mode
Ex t= Manuel operating of extern
motor
Dos = Manuel operating of
dosing motor
Indication of diodes operating:
In each button for each power option there's a LED that can light up yellow, green or both yellow
and green.
When one of the power buttons activates lights diodes as follows:
Yellow and green ignition progress
Yellow and flashing green ignition progress-electric coil active
Green – Combustion running
IA Brännare Flex-a R2 SV
Installationsanvisning Janfire Flex - a
Edit button
DIODER
Power indication
Alarm diodes
Operating indication
Figur 4 Control panel
© Janfire 2009
)