Adjustment Of The Fan Speed; Adjustment Of Pellet Feeding - Janfire Flex-a Installation And Service

Pellet burner
Table of Contents

Advertisement

Fan preference mode
Setting for feeding time
Setting the external motor access time
Setting for maintenance time end mode

3.4 Adjustment of the fan speed

Fan-preference mode activates by press both edit and Ext buttons in 5 sec and release when
edit/Status diode is switch off. When you release the buttons-edit/Status diode is blinking once.
This shows that fan-preference mode is active.
Select the fan mode will be adjusted by pressing each button as follows:
1 = Fan setting for the power mode 1 (60V)
2 = Fan setting for the power mode 2 (75V)
3 = Fan setting for the power mode 3 (90V)
4 = Fan setting for the power mode 4 (120)
M = fan setting for ignition (87V)
Connect the voltmeter to the underside of the burner and control the voltage.
Press "Ext" to reduce voltage
Press "Dose" to increase voltage
Press "Stop" to save the new setting.
If mode changes without saving returns settings to previously saved value.

3.5 Adjustment of pellet Feeding

Press edit button from Fan setting mode to activate feeding sttings mode.
Alarm diodes uses for display of feeding time.
Feeding time is normally 1.0 sec. In this case, only the diode in the middle (elspiral) shine.
Each press to Ext (left button) decreases time for 0.1 sec.
Each press to Dos (right button) increases time for 0.1 sec.
IA Brännare Flex-a R2 SV
Installationsanvisning Janfire Flex - a
© Janfire 2009
)
13(19