4. OPERATION
 WARNING! Be careful when inserting or removing the bore scope shaft into, and out of, the equipment
under inspection.
Before and after use, check the bore scope for tears and abrasions.
Check the bore scope for correct lighting operation. If dim, or no lighting evident, replace the batteries.
Check the bore scope for smooth eyepiece rotation.
4.1. Note the location of the object to be inspected and determine a route to it. Bend the bore scope shaft to
follow the route.
4.2. DO NOT bend the bore scope shaft tighter than Ø76mm.
4.3. DO NOT expose the bore scope housing to water or other liquids.
4.4. DO NOT insert the bore scope shaft into locations whose temperature is greater than 70°C.
4.5. DO NOT use the bore scope close to moving parts such as gears, fan blades or moving belts.
5. MAINTENANCE
Battery Replacment
 WARNING! Disconnect the bore scope prior to carrying out maintenance or battery replacement.
Be careful when inserting, or removing, the battery pack so as not to strain or damage the connecting
leads. REFER TO FIG 2.
3.1. Remove the battery housing door with a Phillips screwdriver.
3.2. Tilt the battery pack from the bottom of the bore scope handle and remove it.
3.3. Unclip the connector - if required - and replace the batteries.
3.4. Re-attach the connector and relocate the battery pack in the bore scope handle.
3.5. Replace the battery housing door using a Phillips screwdriver.
Lighting
3.6. The VS819900 bore scopes are equipped with integrated, solid-state LED lamps. These lamps are
designed to be maintenance-free for the life of the instrument.
Cleaning and Storage
3.7. Wipe the bore scope tip, shaft and housing with a clean, soft cloth to remove residue and moisture.
3.8. Wash the bore scope tip and shaft with a cleaning liquid and rinse with water, then dry.
3.9. Gently clean the Distal Tip lens and eyepiece with a lens cleaner such as isopropyl alcohol and a cotton
bud.
NOTE: The bore scope MUST be completely dry prior to returning it to the storage case.
Fig 2
Declaration of Conformity We, the sole importer into the UK, declare that the product listed here is in conformity with the following standards and directives.The
construction file for this product is held by the Manufacturer and may be inspected, by a national authority, upon request to Jack Sealey Ltd.
Bore Scope Model No:
2002/95/EC RoHS Directive
2002/96/EC WEEE Directive
93/68/EEC CE Marking Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
VS819900
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
Signed by Tim Thompson
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
01284 757500
01284 703534
Fig 3
Fig 4
14th October 2006
www.sealey.co.uk
Web
sales@sealey.co.uk
email
VS819900
Issue: 1 - 14/10/08

Advertisement

loading