Download Print this page

Specification; Air Supply; Operation - Sealey YAJ15-30.V2 Instruction Manual

Air operated jacks telescopic

Advertisement

3. SPECIFICATION

Note: The maximum heights shown may be extended by use of the extension pins.
Model No
YAJ15-30.V2
Maximum
30Tonne
Capacity
Minimum
175mm
Height
Maximum Height/Capacity (mm/Tonne)
Stage 1
393/30
Stage 2
472/15
Extension 45/75mm
Chassis
480mm
Length
Length inc. Handle
Position 1
460mm
Position 2
1380mm
Position 3
1700mm
Width
290mm
Working
116-
Pressure
145psi
Air Flow
10.5cfm
Weight
39kg
4. ASSEMBLY
4.1.
Attaching the Handle - YAJ15-30.V2, YAJ20-40.V2, YAJ20-40LR
4.1.1.
Remove a circlip from either side of the large pin (fig.1A).
4.1.2.
Slide out the pin and place the handle into the opening. Slide the pin back through the jack, lining up the handle and through the
other side. Secure with circlips.
4.2.
Air Hoses - YAJ15-30.V2, YAJ20-40.V2, YAJ20-40LR
4.2.1.
Screw in the two air hoses from the handle into the jack.
4.2.2.
The hose marked orange must be screwed into the left-hand side. The hose marked black or clear into the right-hand side, (fig.1).
4.2.3.
Ensure the hoses are tight and do not obstruct the movement of the handle.

5. AIR SUPPLY

5.1.
Ensure that the jack pneumatic switch is in the "off" position before connecting to the air supply.
5.2.
You will require an air pressure of at least 116psi (max 145psi or 174psi for YAJ20-40LR) and an air flow of 10.5cfm (or 11.5cfm for
YAJ20-40LR) to get the best performance from this jack.
WARNING! Ensure the air supply does not exceed 145psi (or 174psi for YAJ20-40LR) while operating the jack.
R
Too high an air pressure and unclean air will shorten the products life due to excessive wear, and may be dangerous causing
possible damage and personal injury.
5.3.
Drain the air tank daily. Water in the air line will damage the jack.
5.4.
Clean the air inlet filter screen weekly.
5.5.
Keep the air hose between the compressor and the air jack as short as possible, and install an air filter and oiler (fig.2).
5.6.
Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should
be 3/8" I.D. and fittings must have the same inside dimensions.
5.7.
Keep hose away from heat, oil and sharp edges. Check hoses for wear, and make certain that all connections are secure.
fig.2

6. OPERATION

6.1.
PREPARATION - YAJ15-30.V2, YAJ20-40.V2, YAJ20-40LR
6.1.1.
You will require an air pressure of at least 116psi (max 145psi or 174psi for YAJ20-40LR) and an air flow of 10.5cfm or 11.5cfm for
YAJ20-40LR to get the best performance from the jack.
6.1.2.
Connect the air supply to the connector (fig.3B).
6.1.3.
Set the handle to the required angle using the handle release lever shown in fig.3A. Pull the lever upwards towards the main
handle. Move the handle to the required position and release the lever to lock it into position.
6.2.
PREPARATION - YAJ15-30DC.V2, YAJ20-40DC.V2
6.2.1.
Connect the air supply to the connector (fig.4A).
6.2.2.
To change the handle position on the "DC" models turn the handle (fig.4D) anti-clockwise then pull out of socket, insert into the
other handle socket and turn clockwise to secure.
6.3.
PURGE THE SYSTEM - YAJ15-30.V2, YAJ20-40.V2 AND YAJ20-40LR
6.3.1.
Before using the jack, purge the hydraulic circuit in order to eliminate any possible air that may have entered the system during
transit.
6.3.2.
Push the control lever (fig.5A) to the 'down' position and hold it there for several seconds.
© Jack Sealey Limited
YAJ15-30DC.V2
YAJ20-40.V2
YAJ20-40DC.V2
30Tonne
40Tonne
40Tonne
150mm
175mm
150mm
343/30
393/40
343/40
409/15
472/20
409/20
45/75mm
45/75mm
45/75mm
430mm
480mm
430mm
1280mm
460mm
1280mm
1600mm
1380mm
1600mm
-
1700mm
-
290mm
290mm
290mm
116-
116-
116-
145psi
145psi
145psi
10.5cfm
10.5cfm
10.5cfm
31kg
41kg
33kg
Original Language Version
YAJ20-40LR
fig.1
40Tonne
190mm
416/40
504/20
45/75mm
770mm
820mm
1770mm
2100mm
282mm
116-
174psi
11.5cfm
62kg
YAJ15-30.V2, YAJ15-30DC.V2,YAJ20-40.V2,
YAJ20-40DC.V2, YAJ20-40LR| Issue 2 (I) 28/04/15

Advertisement

loading

This manual is also suitable for:

Yaj15-30dc.v2Yaj20-40.v2Yaj20-40dc.v2Yaj20-40lr