Hitachi SJ2-CO Instruction Manual page 26

For sj200-2/l200-2 series inverters
Hide thumbs Also See for SJ2-CO:
Table of Contents

Advertisement

6.4 LED display and Countermeasure
Following states are indicated by Module LED and CANopen status LED.
MOD (Module status) LED: It indicates Inverter condition.
CAN (CANopen status) LED: it indicates CANopen status.
LED
Color
Green ON
Green
single flash
Red ON
MOD
Red single
flash
OFF
Green ON
Green
single flash
Green
Blinking
CAN
OFF
Red single
flash
Red double
flash
notes
LED ON:
constantly on
LED OFF:
constantly off
LED blinking:
iso-phase on and off with a frequency of approximately 2.5Hz:
on for approximately 200ms and off for approximately 200ms.
LED single flash:
one short flash (approximately 200ms) followed by a long off phase (approximately 1000ms).
LED double flash:
a sequence of two short flashes (approximately 200ms),
separated by an off phase (approximately 200ms).
The sequence is finished by a long off phase (approximately 1000ms).
All manuals and user guides at all-guides.com
CHAPTER6 COUNTERMEASURE FOR ABNORMALITY
State
The inverter is in Normal
condition.
The inverter is in Stand-by
condition.
An
abnormality
occurred
which is impossible to restore.
An
abnormality
occurred
which is possible to restore.
Mostly this state occurs, when
the inverter is in trip condition.
But except status below.
User initializing with b084 set
to 01 or 02.
Power off
OPERATIONAL
STOPPED
PRE-OPERATINAL
no error
Warning limit reached
Error Control Event
Countermeasure
-
-
Need to fix the inverter.
When in trip, remove the trip
causes.
When initializing, the inverter
starts
up
automatically
BOOTUP process after the
initializing.
-
-
-
-
-
Any Flaming error
The Guarding Protocol or the
Heartbeat
Protocol
processing.
22
Category
Mandatory
Mandatory
Mandatory
Mandatory
the
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
Mandatory
is