Furuno DS-80 Installation Manual page 24

Doppler speed log
Hide thumbs Also See for DS-80:
Table of Contents

Advertisement

13. Apply the Liquid Gasket TB1121 to the thread part of hex. bolt (15) with seal washer (16)
and use them to fasten the transducer. Check that the fore mark on the shaft is aligned with
the projection at the bottom of the transducer.
14. Pass the flat washer (8), gasket (7), washer (8), and the gland (19) onto the transducer
cable.
15. Fasten the gland (19) to the top of the shaft (5).
16. Apply the Liquid Gasket TB1121 to both sides of the gasket2 (18), and put it on the ball
valve (20).
17. Put the shaft on the gasket2 (18), and align the hollow side on the flange (3) with the
projection of the transducer (1).
18. Remove three M8 hex. bolts (13) and three M8 spring washers (14) from the lock ring (6) to
free the shaft (5).
19. Fasten the flange (4) loosely with the M16 hex. bolt (12), M16 nut (10) and M16 flat washer
(11).
18

Advertisement

Table of Contents
loading

Table of Contents