Add Fuel; Grounding - Firman W01782 Operator's Manual

Portable inverter generator
Table of Contents

Advertisement

Available languages

Available languages

Add Fuel

Fuel must meet these requirements:
Clean, fresh, unleaded gasoline.
Use regular UNLEADED gasoline with the
generator engine with a minimum 87 octane
/ 87 AKI (91 RON).
For high altitude use, see "Operation at High
Altitude".
Do not use gasoline with more than 10%
alcohol such as E85 or ethanol.
Avoid generator damage.
Failure to follow Operator's Manual for fuel
recommendations voids warranty.
• •
DO NOT use unapproved gasoline such as E85.
DO NOT mix oil in gasoline.
DO NOT modify engine to run on alternate fuels.
WARNING
Fuel and its vapors are extremely flammable
and explosive which could cause burns, fire or
explosion resulting in death, serious injury.
WHEN ADDING FUEL
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel
expansion. If the tank is overfilled, fuel
can overflow onto a hot engine and cause fire
or explosion. Wipe up any spilled fuel
immediately.
If fuel spills, wait until it evaporates before
starting engine.
Keep fuel away from sparks, open flames,
pilot lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings
frequently for cracks or leaks. Replace if
necessary.
DO NOT light a cigarette or smoke when
filling the fuel tank.
1.Clean area around fuel fill cap, remove cap.
2.Slowly add unleaded fuel to fuel tank. Be
careful not to fill above the red fuel level
indicator . This allows adequate space for
fuel expansion.
3.Install fuel cap and let any spilled fuel
evaporate before starting engine or wipe up
any spilled gasoline.
English
• •
Slowly add unleaded gasoline to fuel tank.
Do not overfill tank.
Do not fill above the red line indicator.
This will allow expansion in hot weather
and prevent overflow.
Red Line Indicator

Grounding

The generator neutral is floating, which means
that the AC stator winding is isolated from the
grounding fastener and the AC receptacle
ground pins. On a floating neutral generator
the AC receptacle ground pins are not functional.
Electrical devices, such as a ground fault circuit
interrupter (GFCI), requiring a functioning AC
receptacle ground pin will not operate.
Page 11
CAUTION
Customer Service: 1-844-FIRMAN1

Hide quick links: