Page 1
OWNER’S MANUAL PORTABLE INVERTER GENERATOR MODEL NUMBER W03383 Rev Level:00 IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Ensure engine is stopped and level before performing any maintenance or service. Record product information to reference when ordering parts or obtaining warranty coverage.
Page 2
FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
Save these original instructions for future reference. This manual covers operation and maintenance of the FIRMAN generators. All information in this publication is based on the latest production information available at the time of approval for printing.
SAFETY PRECAUTIONS • WARNING POISONOUS GAS HAZARD. • • • • English Page 02 Customer Service: 1-844-FIRMAN1...
Page 6
CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: Near any door, window or vent Garage Basement...
Page 7
WHEN OPERATING EQUIPMENT WARNING • DO NOT operate this product inside any S t a r t e r c o r d k i c k b a c k ( r a p i d building, carport, porch, mobile equipment, retraction) will pull hand and arm marine applications, or enclosure.
Page 8
• When using generator for backup power, WARNING notify utility company. Unintentional sparking • Use a ground fault circuit interrupter (GFCI) could cause fire or in any damp or highly conductive area, electric shock resulting such as metal decking or steel work. in death or serious •...
CONTROLS AND FEATURES ① ② Generator ① ⑧ ③ ⑥ ④ ⑤ ⑦ 1- Fixed Carrying Handle 2- Fuel Cap 3- Recoil Starter 4- Never Flat Wheel 5- Control Panel 6- Muffler/Spark Arrester 7- Maintenance Cover – Oil filler and air filter access. 8- Folding Handle *We are always working to improve our products.
Control Panel NOTE: Total power drawn from all receptacles must not exceed the name plate rating. Engine Start Switch – Used to start engine from Overload Indicator Light – This light turns “ON” when the generator is overloaded and will cut the starter motor(Electric start model only).
Before the generator can be started , an initial Parallel Operation Outlets - These outlets are used start-up procedure must be performed so the for connecting two FIRMAN inverter generators for generator and the remote control recognize parallel operation. A FIRMAN parallel kit(optional each other.
5. Push the "START" button on the remote Battery Cable Connection control and hold on. Release the button when Follow below instruction to connect battery to the indicator light become off. the generator: 1.Unscrew the air cleaner cover by provided START screwdriver.
Floating Neutral AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Firman Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed, your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be brought back within this range before operation.
Add Engine Oil CAUTION DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage to the generator as a result of failure to follow these instructions will void your warranty. NOTE: The recommended oil type is 10W-30 automotive oil.
Add Fuel Fuel must meet these requirements: • Clean, fresh, unleaded gasoline. • Use regular UNLEADED gasoline with the generator engine with a minimum 87 octane / 87 AKI (91 RON). For high altitude use, see "Operation at High Altitude". •...
Customer Support. Installation instructions are also available Connections for standby power to a building's in the Technical Bulletin area of the FIRMAN internet electrical system must be made by a qualified site. electrician. The connection must isolate the...
• OPERATION Operate this product ONLY outside far away from windows, doors and vents to reduce Generator Location the risk of carbon monoxide gas from accumulating and potentially being drawn WARNING towards occupied spaces. • Make sure you review each warning in order to Install battery-operated carbon monoxide prevent fire hazard.
Starting the Generator (Recoil Start) 1. Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment. 2. Check oil level and fuel. 7. Push the choke button to the “CHOKE” position. 3.
Keep choke lever in “CHOKE” position for only 1 pull of the recoil starter. After first pull, move choke lever to the “RUN” position for up to the next 3 pulls of the recoil starter. Too much choke leads to sparkplug fouling/engine flooding due to the lack of incoming air.
Starting the Generator (Electric Start) 4. Turn the fuel valve to the “ON”(l) position. Electric Start and Remote Start Operations WARNING 5. Flip the engine switch to the "RUN"(l) position. WARNING 6. Push the battery power restore switch for about 3 seconds and then release.
9. Push the choke button to the “RUN” position. 4. Turn the fuel valve to the “ON”(l) position. 10. Allow generator to run at no load for few 5. Flip the engine switch to the "RUN"(l) position. minutes upon each initial start-up to permit engine and generator to stablize.
8. Allow generator to run at no load for few minutes upon each initial start-up to permit Connecting a generator to your electric utility engine and generator to stablize. company’s power lines or to another power source may be against the law. In addition this Remote Control Power Consumption action, if done incorrectly, could damage your While the Engine Switch is in the “RUN”...
12V DC Outlet (Battery Charger) 3. Connect the red (+) battery charger lead to the red (+) battery terminal. The 12V DC outlet is ONLY to be used with the 4. Connect the black (–) battery charger lead to supplied 12V battery charging cable. The DC the black (–) battery terminal.
1.DO NOT try to restart the engine. Any two FIRMAN inverter generator with parallel 2.Contact an Authorized FIRMAN Service Dealer. port including two FIRMAN inverter model W03383 3.DO NOT operate engine until oil level is corrected. can be paralleled to increase the total available If oil level is below the LOW mark on dipstick: electrical power to 6000 Watts.
ENGINE MAINTENANCE • Use fresh and high quality lubricating oil to the To prevent accidental starting, remove and specified quantity. ground spark plug wire before performing any If contaminated or deteriorated oil is used or service. the quantity of the engine oil is not sufficient, Change Engine Oil the engine damage will result and its life will be greatly shortened.
Spark Plug Maintenance Inspect Muffler and Spark Arrester Changing the spark plug will help your engine Inspect the muffler for cracks, corrosion, or to start easier and run better. other damage. Remove the spark arrester, if (a) Remove the maintenance cover. equipped, and inspect for damage or carbon blockage.
3. Carefully remove the carbon deposits from the Battery Replacement spark arrester screen with a wire brush. 1.Unscrew the air cleaner cover by provided screwdriver. 4. Replace the spark arrester if it is damaged. 5. Position the spark arrester in the muffler and 2.
ALWAYS disconnect the negative (-) battery cable (black boot) first when disconnecting battery cables. NEVER connect the negative (-) battery cable (black boot) to the positive (+) post on the battery. NEVER connect the positive (+) battery cable (red boot) to the negative (-) post on the battery. NEVER touch both battery posts simultaneously.
4-FUEL STARVATION: Start and run the generator SERVICE AND STORAGE until it stops from lack of fuel. This will dry out all remaining fuel in tank, fuel lines and carburetor. Infrequent Service 5-Allow the unit to cool entirely before cleaning If the unit is used infrequently, difficult starting and storage.
TROUBLE SHOOTING Problem Cause Correction 1. Circuit breaker is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord 3. Check and repair. AC output is available. set.
W03383 Parts List Qty. Qty. NO. Part Number NO. Part Number Description Description 330713566 330713500 Fuel Tank Cap Fixed Handle,Left Supporter,Handle Left(Engine) 330713567 330713501 Spillway,Fuel Tank 330713568 Supporter,Handle Right(Engine) 330713502 Screw M5×20 330713569 Cover,Left Side 330713503 Cover,top 330713570 Screw ST4.8×13...
Page 36
SPE195ER 193cc Engine Parts List Qty. Qty. NO. Part Number Description NO. Part Number Description Flange Bolt M8×35 Guide Plate,Push Rod 330723500 330723552 330723501 Oil Seal 330723553 Push Rod Cover,crankcase Valve,Intake 330723502 330723554 330723503 Oil Level Sensor 330723555 Stud Bolt(M6×32) Flange BOLT M6×12 Stud Bolt(M6×97) 330723504...
FIRMAN GENERATOR will register the warranty upon DEPARTMENT AT receipt of your Warranty Registration Card and a 1-844-347-6261 copy of your sales receipt from one of FIRMAN's retail locations as proof of purchase. Please submit or at your warranty registration and your proof of purchase www.firmanpowerequipment.com...
Page 38
Peoria, AZ 85381 Normal maintenance is not covered by this www.firmanpowerequipment.com warranty. We are FIRMAN POWER - And we are here for you. Other Exclusions Customer Service Desk - 1-844-347-6261(1-844-FIRMAN1) This warranty excludes: 6am PST(9am EST) until 8pm EST(5pm PST) –...
Page 39
If any such part fails during the period of warranty coverage, the part will be repaired or replaced by FIRMAN at no charge to the owner. Any such part repaired or replaced under the warranty will be warranted for the remaining warranty period.
Page 40
(8) Throughout the emissions warranty period defined in Subsection (b)(2), FIRMAN will maintain a supply of warranted parts sufficient to meet the expected demand for such parts. (9) Any replacement part may be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner.
Page 41
Firman Power Equipment Inc. 8716 West Ludlow Dr. Suite #6 Peoria, AZ 85381 www.firmanpowerequipment.com P/N:333745452 Rev 0 2...
Need help?
Do you have a question about the W03383 and is the answer not in the manual?
Questions and answers