Firman W03383 Owner's Manual
Hide thumbs Also See for W03383:

Advertisement

Quick Links

OWNER'S MANUAL
PORTABLE INVERTER GENERATOR
IMPORTANT:
Record product information to reference when ordering parts or
obtaining warranty coverage.
DO NOT RETURN TO
STORE!
CALL US FIRST!
CUSTOMER HOTLINE
1-844-347-6261
FOR QUESTIONS OR SERVICE
INFORMATION
Read all safety precautions and instructions carefully
before operating equipment.
Ensure engine is stopped and level before performing
any maintenance or service.
MODEL NUMBER
W03383
Serial Number:
Purchase Date:
P/N:333745452 Rev:02
Rev Level:00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W03383 and is the answer not in the manual?

Questions and answers

Summary of Contents for Firman W03383

  • Page 1 OWNER’S MANUAL PORTABLE INVERTER GENERATOR MODEL NUMBER W03383 Rev Level:00 IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Ensure engine is stopped and level before performing any maintenance or service. Record product information to reference when ordering parts or obtaining warranty coverage.
  • Page 2 FCC Statement 1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.
  • Page 3: Table Of Contents

    Table of Contents Introduction ......1 Maintenance And Storage....23 Safety Precautions .
  • Page 4: Introduction

    Save these original instructions for future reference. This manual covers operation and maintenance of the FIRMAN generators. All information in this publication is based on the latest production information available at the time of approval for printing.
  • Page 5: Safety Precautions

    SAFETY PRECAUTIONS • WARNING POISONOUS GAS HAZARD. • • • • English Page 02 Customer Service: 1-844-FIRMAN1...
  • Page 6 CORRECT USAGE Example location to reduce risk of carbon monoxide poisoning • ONLY use outside and downwind, far away from windows, doors and vents. • Direct exhaust away from occupied spaces. INCORRECT USAGE Do not operate in any of the following locations: Near any door, window or vent Garage Basement...
  • Page 7 WHEN OPERATING EQUIPMENT WARNING • DO NOT operate this product inside any S t a r t e r c o r d k i c k b a c k ( r a p i d building, carport, porch, mobile equipment, retraction) will pull hand and arm marine applications, or enclosure.
  • Page 8 • When using generator for backup power, WARNING notify utility company. Unintentional sparking • Use a ground fault circuit interrupter (GFCI) could cause fire or in any damp or highly conductive area, electric shock resulting such as metal decking or steel work. in death or serious •...
  • Page 9: Unpacking The Generator

    NOTE: 1. Engine Oil(Bottle) ..... . . 1 Improper treatment of generator could damage 2. Oil Funnel ....... 1 it and shorten its life.
  • Page 10: Controls And Features

    CONTROLS AND FEATURES ① ② Generator ① ⑧ ③ ⑥ ④ ⑤ ⑦ 1- Fixed Carrying Handle 2- Fuel Cap 3- Recoil Starter 4- Never Flat Wheel 5- Control Panel 6- Muffler/Spark Arrester 7- Maintenance Cover – Oil filler and air filter access. 8- Folding Handle *We are always working to improve our products.
  • Page 11: Control Panel

    Control Panel NOTE: Total power drawn from all receptacles must not exceed the name plate rating. Engine Start Switch – Used to start engine from Overload Indicator Light – This light turns “ON” when the generator is overloaded and will cut the starter motor(Electric start model only).
  • Page 12: Remote Control Programming

    Before the generator can be started , an initial Parallel Operation Outlets - These outlets are used start-up procedure must be performed so the for connecting two FIRMAN inverter generators for generator and the remote control recognize parallel operation. A FIRMAN parallel kit(optional each other.
  • Page 13: Remote Control Power Consumption

    5. Push the "START" button on the remote Battery Cable Connection control and hold on. Release the button when Follow below instruction to connect battery to the indicator light become off. the generator: 1.Unscrew the air cleaner cover by provided START screwdriver.
  • Page 14: Specifications

    Floating Neutral AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Firman Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed, your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods. If the product is exposed to temperatures outside this range during storage, it should be brought back within this range before operation.
  • Page 15: Add Engine Oil

    Add Engine Oil CAUTION DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil. Damage to the generator as a result of failure to follow these instructions will void your warranty. NOTE: The recommended oil type is 10W-30 automotive oil.
  • Page 16: Add Fuel

    Add Fuel Fuel must meet these requirements: • Clean, fresh, unleaded gasoline. • Use regular UNLEADED gasoline with the generator engine with a minimum 87 octane / 87 AKI (91 RON). For high altitude use, see "Operation at High Altitude". •...
  • Page 17: Grounding

    Customer Support. Installation instructions are also available Connections for standby power to a building's in the Technical Bulletin area of the FIRMAN internet electrical system must be made by a qualified site. electrician. The connection must isolate the...
  • Page 18: Operation

    • OPERATION Operate this product ONLY outside far away from windows, doors and vents to reduce Generator Location the risk of carbon monoxide gas from accumulating and potentially being drawn WARNING towards occupied spaces. • Make sure you review each warning in order to Install battery-operated carbon monoxide prevent fire hazard.
  • Page 19: Starting The Generator(Recoil Start)

    Starting the Generator (Recoil Start) 1. Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment. 2. Check oil level and fuel. 7. Push the choke button to the “CHOKE” position. 3.
  • Page 20: Manual Choke Start

    Keep choke lever in “CHOKE” position for only 1 pull of the recoil starter. After first pull, move choke lever to the “RUN” position for up to the next 3 pulls of the recoil starter. Too much choke leads to sparkplug fouling/engine flooding due to the lack of incoming air.
  • Page 21: Starting The Generator (Electric Start)

    Starting the Generator (Electric Start) 4. Turn the fuel valve to the “ON”(l) position. Electric Start and Remote Start Operations WARNING 5. Flip the engine switch to the "RUN"(l) position. WARNING 6. Push the battery power restore switch for about 3 seconds and then release.
  • Page 22: Starting The Generator (Remote Start)

    9. Push the choke button to the “RUN” position. 4. Turn the fuel valve to the “ON”(l) position. 10. Allow generator to run at no load for few 5. Flip the engine switch to the "RUN"(l) position. minutes upon each initial start-up to permit engine and generator to stablize.
  • Page 23: Connecting Electrical Loads

    8. Allow generator to run at no load for few minutes upon each initial start-up to permit Connecting a generator to your electric utility engine and generator to stablize. company’s power lines or to another power source may be against the law. In addition this Remote Control Power Consumption action, if done incorrectly, could damage your While the Engine Switch is in the “RUN”...
  • Page 24: Dc Outlet (Battery Charger)

    12V DC Outlet (Battery Charger) 3. Connect the red (+) battery charger lead to the red (+) battery terminal. The 12V DC outlet is ONLY to be used with the 4. Connect the black (–) battery charger lead to supplied 12V battery charging cable. The DC the black (–) battery terminal.
  • Page 25: Low Oil Shutdown

    1.DO NOT try to restart the engine. Any two FIRMAN inverter generator with parallel 2.Contact an Authorized FIRMAN Service Dealer. port including two FIRMAN inverter model W03383 3.DO NOT operate engine until oil level is corrected. can be paralleled to increase the total available If oil level is below the LOW mark on dipstick: electrical power to 6000 Watts.
  • Page 26: Maintenance And Storage

    MAINTENANCE AND STORAGE MAINTENANCE SCHEDULE Every Daily(Before Initial Every 100 hours ITEM NOTES operation) 25 hours 50 hours (or annual) Check condition. Adjust gap √ Spark Plug and clean. Replace if necessary. √ Check oil level. Engine Oil √ √ Replace.
  • Page 27: Engine Maintenance

    ENGINE MAINTENANCE • Use fresh and high quality lubricating oil to the To prevent accidental starting, remove and specified quantity. ground spark plug wire before performing any If contaminated or deteriorated oil is used or service. the quantity of the engine oil is not sufficient, Change Engine Oil the engine damage will result and its life will be greatly shortened.
  • Page 28: Spark Plug Maintenance

    Spark Plug Maintenance Inspect Muffler and Spark Arrester Changing the spark plug will help your engine Inspect the muffler for cracks, corrosion, or to start easier and run better. other damage. Remove the spark arrester, if (a) Remove the maintenance cover. equipped, and inspect for damage or carbon blockage.
  • Page 29: Generator Maintenance

    3. Carefully remove the carbon deposits from the Battery Replacement spark arrester screen with a wire brush. 1.Unscrew the air cleaner cover by provided screwdriver. 4. Replace the spark arrester if it is damaged. 5. Position the spark arrester in the muffler and 2.
  • Page 30: Battery Replacement On Remote

    ALWAYS disconnect the negative (-) battery cable (black boot) first when disconnecting battery cables. NEVER connect the negative (-) battery cable (black boot) to the positive (+) post on the battery. NEVER connect the positive (+) battery cable (red boot) to the negative (-) post on the battery. NEVER touch both battery posts simultaneously.
  • Page 31: Service And Storage

    4-FUEL STARVATION: Start and run the generator SERVICE AND STORAGE until it stops from lack of fuel. This will dry out all remaining fuel in tank, fuel lines and carburetor. Infrequent Service 5-Allow the unit to cool entirely before cleaning If the unit is used infrequently, difficult starting and storage.
  • Page 32: Trouble Shooting

    TROUBLE SHOOTING Problem Cause Correction 1. Circuit breaker is open. 1. Reset circuit breaker. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no 3. Poor connection or defective cord 3. Check and repair. AC output is available. set.
  • Page 33: Parts Diagram And Parts List

    PARTS DIAGRAM AND PARTS LIST W03383 Parts Diagram Page 30 English Customer Service: 1-844-FIRMAN1...
  • Page 34: Engine Parts Diagram

    193cc Engine Parts Diagram Page 31 English Customer Service: 1-844-FIRMAN1...
  • Page 35: Parts List

    W03383 Parts List Qty. Qty. NO. Part Number NO. Part Number Description Description 330713566 330713500 Fuel Tank Cap Fixed Handle,Left Supporter,Handle Left(Engine) 330713567 330713501 Spillway,Fuel Tank 330713568 Supporter,Handle Right(Engine) 330713502 Screw M5×20 330713569 Cover,Left Side 330713503 Cover,top 330713570 Screw ST4.8×13...
  • Page 36 SPE195ER 193cc Engine Parts List Qty. Qty. NO. Part Number Description NO. Part Number Description Flange Bolt M8×35 Guide Plate,Push Rod 330723500 330723552 330723501 Oil Seal 330723553 Push Rod Cover,crankcase Valve,Intake 330723502 330723554 330723503 Oil Level Sensor 330723555 Stud Bolt(M6×32) Flange BOLT M6×12 Stud Bolt(M6×97) 330723504...
  • Page 37: Service Information

    FIRMAN GENERATOR will register the warranty upon DEPARTMENT AT receipt of your Warranty Registration Card and a 1-844-347-6261 copy of your sales receipt from one of FIRMAN's retail locations as proof of purchase. Please submit or at your warranty registration and your proof of purchase www.firmanpowerequipment.com...
  • Page 38 Peoria, AZ 85381 Normal maintenance is not covered by this www.firmanpowerequipment.com warranty. We are FIRMAN POWER - And we are here for you. Other Exclusions Customer Service Desk - 1-844-347-6261(1-844-FIRMAN1) This warranty excludes: 6am PST(9am EST) until 8pm EST(5pm PST) –...
  • Page 39 If any such part fails during the period of warranty coverage, the part will be repaired or replaced by FIRMAN at no charge to the owner. Any such part repaired or replaced under the warranty will be warranted for the remaining warranty period.
  • Page 40 (8) Throughout the emissions warranty period defined in Subsection (b)(2), FIRMAN will maintain a supply of warranted parts sufficient to meet the expected demand for such parts. (9) Any replacement part may be used in the performance of any warranty maintenance or repairs and must be provided without charge to the owner.
  • Page 41 Firman Power Equipment Inc. 8716 West Ludlow Dr. Suite #6 Peoria, AZ 85381 www.firmanpowerequipment.com P/N:333745452 Rev 0 2...