Download Print this page

JVC AV-14FR10 Service Manual page 31

Advertisement

STATIC CONVERGENCE ADJUSTMENT
1. Input a crosshatch signal.
2. Using 4-pole convergence magnets, overlap the red and blue
lines in the center of the screen (Fig.1) and turn them to
magenta (red/blue).
3. Using
6-pole
convergence
magenta(red/blue) and green lines in the center of the screen
and turn them to white.
4. Repeat 2 and 3 above, and make best convergence.
DYNAMIC CONVERGENCE ADJUSTMENT
1. Move the deflection yoke up and down and overlap the lines in
the periphery. (Fig. 2)
2. Move the deflection yoke left to right and overlap the lines in the
periphery. (Fig. 3)
3. Repeat 1 and 2 above, and make best convergence.
After adjustment, fix the wedge at the original position.
Fasten the retainer screw of the deflection yoke.
Fix the 6 magnets with glue.
magnets,
overlap
the
No. 51865
(FRONT VIEW )
Fig.1
(FRONT VIEW )
RED
GREEN
BLUE
GREEN
RED
BLUE
GREEN
Fig.2
(FRONT VIEW )
GREEN
RED
BLUE
Fig.3
AV-14FR10/AV-14F10
AV-1434TEE/AV-1434EE
AV-14FTT2/AV-14FTG2
BLUE
RED
GREEN
BLUE
RED
GREEN
BLUE
RED
RED
GREEN
BLUE
BLUE
GREEN
RED
31