AV-14FTT2/AV-14FTG2
Measuring
Item
instrument
Signal
Adjustment
generator
of VER. LIN.
& VER.
Remote
SCURVE
control unit
Fig.3
28
Test point
Adjustment part
4. VER. LIN.
5. VER. SCURVE
TOP
CENTER
BOTTOM
No. 51865
Description
● ● ● ● When the vertical linearity has been deteriorated
remarkably, perform the following steps.
13. Input a cross-hatch signal.
14. Select 4. VER. LIN. with the MENU ▼ / ▲ key.
15. Set the initial setting value of 4. VER LIN. with the MENU - / +
key.
16. Select 5. VER. SCURVE with the MENU ▼ / ▲ key.
17. Set the initial setting value of 5. VER. SCURVE with the
MENU - / + key.
18. Adjust 4. VER. LIN. and 5. VER. SCURVE so that the spaces
of each line as shown in Fig.3 on TOP, CENTER and
BOTTOM become uniform.
Make sure that the adjustment is properly done on the screen of
60Hz mode.
[NOTE]
!
Adjust to make both 50Hz & 60Hz are the same v. size and
fine straight line.
!
When adjust again, adjust 50Hz mode first.
!
When adjust in 60Hz mode, only 60Hz mode is adjust.