Summary of Contents for Moxa Technologies DR-45 Series
Page 1
DR-45 Series Quick Installation Guide Edition 1.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel: +49-89-3 70 03 99-0...
Page 2
Dimensions Terminal Pin No. Assignments PIN No. Assignment 1, 2 AC Input 4, 5 DC Output V- 6, 7 DC Output V+ LED lit for DC OK +V ADJ Mounting Instructions Mounting: Mount only as shown in figure, with input terminals facing upwards to allow sufficient cooling.
Page 3
Installation 1. To prevent the unit from overheating, always allow sufficient clearance around the unit for proper ventilation: 5 mm left and right, 40 mm above, and 20 mm below. You should also keep a 10 to 15 cm clearance from adjacent devices that act as a heat source. 2.
Page 4
Important Safety Precautions Before working with a power supply, be sure to read and understand these instructions carefully and completely. You should also follow any notes or instructions on the unit itself. 1. Risk of electrical shock and energy Hazard: If the device fails, it must be examined by a qualified technician.