5.6 Power Consumption Display

This function displays the power consumption of the outdoor unit compressor.
The value of each displayed in Graph/List format is 1 day (24h (- every 2 hrs.)), 1 week (7 days), and 1 year (12
months).
NOTES:
The numerical value is a reference. Do not use this unit for the following: calculation of power rates,
examination of the power contract, or calculation of greenhouse gas emissions.
This cannot be set if the power savings function is not supported.
In following instances, the calculated value may be a deficit or may be changed.
○ Power Failure (outdoor unit, indoor unit, wired controller)
○ Communication Failure (outdoor unit ↔ indoor unit ↔ wired controller)
○ Modification of time
indicates that schedule control is not possible. Refer to "6.1 Adjusting Date/Time" to set the date and
time.
1. Set power consumption display
Step1. Select "Power Consumption Display" on the "Function
Menu" screen and press "OK".
If the current time is not set, the "Adjusting Date/Time"
setting screen is displayed.
Step2. Press "OK".
Step3. Press " " or " " to select the display period, and then press "OK".
It switches in the order of 1 day (24 hours) ↔ 1 week (7 days) ↔ 1 year (12 months).
Power Consumption [dd] kWh
Daily
Weekly
100
1000
50
500
Mon
Tue
Wed
Thu
0 2
4
6
8 10 12 14 16 18 20 22
Today
1d bef
This W
OK
Select
Comparison
Press " " or " " to switch the comparison target for the
display period.
2 days before / 1 day before ↔ 1 day before / Today
2 week ago / 1 week ago↔ 1 week ago / This week
2 years ago / 1 year ago ↔ 1 year ago / This year
Display scale
Press " " or " " to switch the display scale.
Graph ↔ List display
Press "OK" to switch between the graph and list display
of the power consumption display.
Press " " to return to the display period selection screen.
A11766820A
Power Consumption [wk] kWh
Daily
10000
100
5000
50
Fri
Sat
Sun
1 2
0 2
4
6
8 10 12 14 16 18 20 22
1w ago
Today
Back
OK
Select
Weekly
Weekly
1000
10000
500
5000
Mon
Tue
Wed
Thu
Fri
Sat
Sun
1 2
1d bef
This W
1w ago
Back
5. Function Menu Screen Display
Function Menu
Power Consumption Display
Autoboost
Comfort Setting
Motion Sensor Setting
Setback Setting
OK
Select
Power Consumption
Usage amount display shows an
approximate value. It cannot be used for
tariff prorata.
OK
OK
OK
Select
Power Consumption [yy] kWh
Weekly
1000
10000
500
5000
Mon
Tue
Wed
Thu
Fri
Sat
Sun
16 18 20 22
1 2 3 4 5 6 7 8 9 10 11 12
bef
This W
1w ago
OK
Select
Power Consumption
[dd] kWh
100
50
0 2
4
6
8 10 12 14 16 18 20 22
1day before
2day before
OK
List
Today
Adjust
Power Consumption
[dd] kWh
Period
1d bef
0 ~ 2
0.0
2 ~ 4
0.0
4 ~ 6
20.5
6 ~ 8
10.2
8 ~ 10
8.5
OK
Graph
(Mon) 16:30
Back
Back
Yearly
This Y
1Y ago
Back
(Mon) 16:30
Back
(Mon) 16:30
2d bef
25.5
10.1
0.0
0.5
5.2
Back
27