Otor Connections - Farr Gold Series Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

330.1 Motor Connections
WARNING! Failure to perform an approved Lock-out/Tag-out procedure may result in a sudden
release of energy resulting in property damage, personal injury or death! Ensure that the circuit
you are working with is off before you make these or any other electrical connections. Serious
injury may result if you do not take proper safety precautions!
Farr can supply the fan, motor starter, and rotary air locks (or other discharge devices) for our dust
collectors. However, the customer or Farr representative may elect to supply the fan and other
accessories. It is imperative that all equipment installed complies with your local electrical code. Check
your paper work and information plates to determine electrical specifications for your equipment.
Mount the motor starter enclosure in a convenient location for operation. Use the enclosure as a template
for marking and drilling mounting holes. Possible locations include a support leg or plant wall near the
collector.
Run conduit and wiring (supplied by others) from the motor starter to the fan motor and from the power
source to the motor starter. The wiring diagram for the motor will be either on the motor or inside the
motor junction box. Connect the wiring from the motor starter to the fan and from the power source to the
motor starter. A qualified electrician should only make these connections.
NEMA 12
ENCLOSURE
Camfil Farr P/N
SIZE
P/N
207267201
207267202
207267203
12X12X6
HFA1212CH
207267204
207267205
207267206
207267207
207267208
16X14X8 HFA16148CH
207267209
207267210
207267211
207267212
207267213
207267214
207267215
12X12X6 HFA1212CH
207267216
207267217
207267218
207267219
207267220
207267221
16X14X8 HFA16148CH
207267222
207267223
AB - Allen Bradley
Camfil Farr Motor Starters
NEMA 4
PANEL BK
Camfil Farr P/N
SIZE
207267401
207267402
207267403
A12P12
12X12X6 A1212CHNF
207267404
207267405
207267406
207267407
207267408
A16P14
16X12X8 A16148CHNF
207267409
207267410
207267411
207267412
207267413
207267414
207267415
A12P12
12X12X6 A1212CHNF
207267416
207267417
207267418
207267419
207267420
207267421
A16P14
16X12X8 A16148CHNF
207267422
207267423
Table 330.1.1
MOTOR LOAD SPECIFICATIONS
ENCLOSURE
230 V
208 V
P/N
PANEL BK
HP
1.5
2
3
A12P12
5
7.5
10
15
20
CP1612
25
30
460V
1.5
2
3
5
7.5
A12P12
10
15
20
25
30
40
CP1612
50
60
CONTACTOR
HP
AMPS
AB P/N
AMPS
1.5
12
AB100C12L10
3.7-12
2
3
NA
16
AB100C16L10
12-32
5
23
AB100C23L10
7.5
AB100C30L10 12-37 193-EA1HC
30
10
AB100C43L10 14-45
43
15
60
AB100C60L10
20
26 - 85 193-EA1KE
72
AB100C72L10
25
85
AB100C85L10
1.6 - 5
1.6 - 5
9
AB100C09B10
3.7-12
3.7-12
12
AB100C12B10 12-32
16
AB100C16B10 12-32
23
AB100C23B10 12-32
30
AB100C30B10 12-37
37
AB100C37B10 12-37
43
AB100C43B10 14-45
60
AB100C60B10 26 - 85
72
AB100C72B10 26 - 85
85
AB100C85B10 26 - 85
18
RELAY
AB P/N
193-EA1FB
193-EA1GB
193-EA1JD
193-EA1EB
193-EA1FB
193-EA1GB
193-EA1HC
193-EA1JD
193-EA1KE

Hide quick links: