Vega Absolute SI-13 User Manual page 5

Lorawan device
Hide thumbs Also See for SI-13:
Table of Contents

Advertisement

Vega SI-13 / User Manual
Hold the
start button
"Active" mode back to the "Storage" mode.
When switching to the "Storage" mode, all readings from the pulse inputs
accumulated in the device memory are reset
The device forms the data packet with current state with a configurable period from 5
minutes to 24 hours. The packets stored in the device memory and transmitting during the
next communication session with the LoRaWAN
Examples
If the data collection period is set to 24 hours the packet is formed at 00.00 on the
internal clock of the device
If the data collection period is 12 hours then at 00.00 and at 12.00, and so on.
The adjustable data transfer period can be from 5 minutes to 24 hours. When
beginning of communication session, the device starts sending packets with readings from
the earliest packet. The time of data transmitting cannot be specified, it's defined in random
way for every device in chosen period of transmission from the moment of connection to the
network.
Example
Transmission period is 30 minutes, and device was started at 16:40 by the internal
device clock. In random way the device calculate data transmitting time and set it at 16:41 in
the half-hour period from 16:40 to 17:10. Thus, packets from this device will transmit at 16:41,
at 17:11, at 17:41, at 18:11 and so on every 30 minutes by the internal device clock.
The internal clock is set automatically when you connect to the device through USB,
also can be adjust via LoRaWAN
of
14
06 August 2021
Revision №
pressed (more than 5 seconds) to switch the device from the
network.
®
network.
®
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Si-13-232Si-13-485