Vega Absolute SI-13 User Manual page 19

Lorawan device
Hide thumbs Also See for SI-13:
Table of Contents

Advertisement

Vega SI-13 / User Manual
Table of ID of SI-13 parameters and these possible values
ID of
Description
parameter
4
Confirmed uplinks
8
Uplinks number of transmissions
16
Communication period
20
Interface speed
49
Data collection period
55
Time zone, in minutes
1.
Revision № 14 of 06 August 2021
Data
Possible values
length
1 byte
1 – confirmed
2 – unconfirmed
1 byte
from 1 to 15
1 байт
1 – 1 hour
2 – 6 hours
3 – 12 hours
4 – 24 hours
5 – 5 minutes
6 – 15 minutes
7 – 30 minutes
1 byte
1 – 4800
2 – 9600
3 – 14400
4 – 19200
5 – 38400
6 – 57600
7 – 115200
8 – 300
9 – 600
10 – 1200
11 – 2400
1 байт
1 – 1 hour
2 – 6 hours
3 – 12 hours
4 – 24 hours
5 – 5 minutes
6 – 15 minutes
7 – 30 minutes
2 bytes
from -720 to 840
19