Philips Magnavox 19MD358B Service Manual page 53

Hide thumbs Also See for Magnavox 19MD358B:
Table of Contents

Advertisement

Table 8-8 Reading in Minolta CA-210.
Normal/ (7500
K)
x (center)
0.300 ± 0.010 0.314 ± 0.010 0.285 ± 0.010
y (center)
0.310 ± 0.010 0.324 ± 0.010 0.293 ± 0.010
Y (center)
180
19PFL3403D
Equipment Requirements: Minolta CA-110 or CA-210 or
Equivalent Color analyzer Chroma 2250 or equivalent PC
signal generator
Input requirements:
Input Signal Type: PC VGA signal
1. 1024X768/60Hz PC mode with 5 white block pattern. (see
pattern-1)
2. Select Color temperature to Normal and check the x, y data.
Input Signal Strength : 0.7 Vp-p linear voltage.
Input Injection Point : PC D-SUB input
Alignment method :
Initial Set-up:
1. Select source as "PC".
2. Set Contrast=50, Brightness=50, Color temperature=
Normal and Picture format= Full screen.
3. Apply "5 white block" pattern by VGA pattern generator.
4. Enter factory mode menu: press MENU + Numeric keys
"062596" + INFO key (FAC mode menu). Then select "Factory"
item.
5. Check Factory setting should be follow up the item10. Preset
NVM data.
Table 8-9 Reading in Minolta CA-110 or CA-210.
Normal/ (7500
K)
x (center)
0.300 ± 0.005 0.314 ± 0.005 0.285 ± 0.005
y (center)
0.310 ± 0.005 0.324 ± 0.005 0.293 ± 0.005
Y (center)
Figure 8-2 "AUTO_COLOR" with five white block pattern.
Warm/(6500
Cool/(9300 K)
K)
Warm/(6500
Cool/(9300 K)
K)
I_17550_013.eps
130208
Alignments
TPM1.1U LA
Figure 8-3 "AUTO_COLOR" with five white block pattern.
8.1.4
HDMI MODE ADJUSTMENT(19PFL3403D)
White balance adjustment (B)
Equipment Requirement: Minolta CA-110 or CA-210 or
Equivalent Color analyzer,Quantum Data Pattern Generator
802BT or 881.
Input requirements:
Input Signal Type: HDMI signal
1. 1080i mode, full white pattern.
2. Select Smart picture to Personal mode and check the x, y
data.
Input Signal Strength : 4 channels TMDS signal
Input Injection Point : HDMI input
Initial Set-up:
1. Select source as "HDMI1 or HDMI2".
2. Set Smart picture as "Personal" and Contrast =50,
Brightness=50, Color=50
3. Apply full white pattern by Quantum Data signal generator.
Table 8-10 Check (X, Y) co-ordinates as belows:
Normal/ (7500
K)
x (center)
0.300 ± 0.005
0.310 ± 0.005
y (center)
Y (center)
Check the gray pattern should be distinguished and color bar is
correct
Check Luminance Note:Use Minolta CA-110 or CA-210 for
colour coordinates and luminance check.
Luminance typical 300 Nits , Min. > 250 Nits
In the center of the screen when "Smart picture" at
"PERSONAL", and Brightness and Contrast control set at
100%
8.2
Serial Number Definition
BOM Code:
Table 8-11 Panel type
PANEL SUPPLIER
AU
CPT
LPL(LG)
QDI
CMO
HSD
SVA
8.
EN 53
I_17550_014.eps
130208
Cool/ (9300 K)
Warm /(6500
K)
0.314 ± 0.005
0.285 ± 0.005
0.324 ± 0.005
0.293 ± 0.005
Code
1
2
3
4
5
6
7

Advertisement