OPERATING PROCEDURE
7. Removing the line flow fan, the indoor fan motor
assembly, the indoor coil thermistor (Photo 9,
10, 11)
(1) Remove the front panel, the horizontal vanes (U) (L),
the panels (R) (L) (F) (U), the Wi-Fi interface (MSZ-
AP∙VGK), the electrical box, and the nozzle assem-
bly.
(2) Loosen the screw inside the right side of the line flow
fan (Photo 9).
(3) Remove the 3 screws of the fan motor assembly.
Pull the fan motor assembly slightly toward you, and
remove it by pulling to the right (Photo 10).
(4) Remove the indoor coil thermistor from the heat
exchanger.
(5) Remove the 2 screws of the hairpin holder on the left
side of the heat exchanger. Raise the left side of the
heat exchanger, and pull the line flow fan to the lower
left to remove (Photo 11).
*1 When attaching the line flow fan, screw the line flow
fan so 4 mm gap is provided between the right end of
the line flow fan and the right wall of the air passage
of the box (Figure 2).
Figure 2
4 mm
OBH788C
PHOTOS/FIGURES
Photo 9
Heat exchanger
Screw of the line flow fan
Photo 10
Photo 11
Hairpin holder
Screws of the left side of the heat exchanger
50
Fan motor
Screws of the fan motor