Ray Johnson
May 30, 2025
What does extreme voltage indicator mean? I have 122v at my power source.
1 comments:
Mr. Anderson
May 30, 2025
When the power source shows 122V, the Extreme Voltage indicator on the Furman PS-8R II will not light. The unit operates normally because 122V is within the acceptable input voltage range and below the extreme voltage cutoff.
Page 1
P S - 8 R I I - P O W E R C O N D I T I O N E R / S E q u E N C E R...
Page 2
Additionally, Furman’s trusted over-voltage cir- cuitry protects against all too frequent acciden- tal connections to 208 or 240 VAC, by shutting off the incoming power until the over voltage condition is corrected. [For E versions: Furman’s SMP+ clamps at 376 VpK, (266 VAC RMS.)]...
Page 3
Worse still, lost digital data, the need to re-boot digital pre-sets, or destroyed digital converters are frequently caused by excessive voltage spikes and AC noise contaminating the equipment ground. Furman’s SMP+ with LiFT takes another approach, ensuring optimal performance through linear filtering and no leakage to ground.
Page 4
P S - 8 R I I - P O W E R C O N D I T I O N E R / S E q u E N C E R switched outlets unswitched outlets. We suggest keeping the front panel unswitched outlet free for equipment that is only in use temporarily.
Page 5
Momentary switches, usually pushbutton types like the Furman RS-2, are normally open and stay closed only as long as the button is pressed. An on-off switch of either kind may be used to actuate...
Page 6
P S - 8 R I I - P O W E R C O N D I T I O N E R / S E q u E N C E R Maintained switches are generally most convenient when there is only one remote location.
NOTE: In Maintained Mode, DO NOT uSE the “START ON-OFF SEQuENCE” switch on the front panel. Doing so may activate an unintended sequence. If a Furman RS-1 is the controlling switch, contact Furman’s Tech Support department for the proper wiring diagrams.
Page 8
If the defects are of such type and nature as to be covered by this warranty, Manufacturer shall authorize Purchaser to return the Product to the Furman factory or to an authorized Furman repair location. Warranty claims should be accompanied by a copy of the original purchase invoice show- ing the purchase date;...
Page 9
NOTE: All equipment being returned for repair must have a Return Authorization (RA) Number. To get an RA Number, please call the Furman Service Department, (707) 763-1010, Ext. 120 or 121, between 8 am and 5 pm u.S. Pacific Time.
Page 10
P S - 8 R I I - P O W E R C O N D I T I O N E R / S E q u E N C E R r e l at e d p r o d u c t s The PS-8R II, along with other Furman AC power accessories, can be an integral part of a complete AC power control system.
Page 11
P S - 8 R I I - P O W E R C O N D I T I O N E R / S E q u E N C E R Maximum Load: PS-8R II: 15 amps (1800 watts at 120 VAC) PS-8R IIE: 10 amps (2300 watts at 230 VAC) Operating Voltage: 90 to 140 VAC (“E”...
Page 12
P S - 8 R I I - P O W E R C O N D I T I O N E R / S E q u E N C E R Furman Sound, LLC. 1997 South McDowell Blvd.
Need help?
Do you have a question about the PS8 R II and is the answer not in the manual?
Questions and answers
What does extreme voltage indicator mean? I have 122v at my power source.
When the power source shows 122V, the Extreme Voltage indicator on the Furman PS-8R II will not light. The unit operates normally because 122V is within the acceptable input voltage range and below the extreme voltage cutoff.
This answer is automatically generated