Blower Data - Lrp16Hp - Lennox LRP14HP Series Manual

Hide thumbs Also See for LRP14HP Series:
Table of Contents

Advertisement

Blower Data – LRP16HP
LRP16HP24 Blower Performance
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
"COOL" Speed - cfm
Setting
A
+
1100
NORM
1000
900
LRP16HP36 Blower Performance
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
"COOL" Speed - cfm
Setting
A
+
1430
1320
NORM
1300
1200
1170
1080
LRP16HP48 Blower Performance
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
"COOL" Speed - cfm
Setting
A
+
1980
1760
NORM
1800
1600
1620
1440
LRP16HP60 Blower Performance
0 through 0.80 in. w.g. External Static Pressure Range
"ADJUST"
Jumper
"COOL" Speed - cfm
Setting
A
+
2200
1980
NORM
2000
1800
1800
1620
Factory Settings.
1
NOTE - All air data is measured external to unit without air
NOTE - 1st Stage
is 70% of 2nd Stage
Blower Control Jumper Speed Positions
B
C
D
1
880
660
440
800
600
400
720
540
360
Blower Control Jumper Speed Positions
B
C
D
1
1100
880
1000
800
900
720
Blower Control Jumper Speed Positions
B
C
D
1
1540
1320
1400
1200
1260
1080
Blower Control Jumper Speed Positions
B
C
D
1
1760
1540
1600
1400
1440
1260
(full capacity) in cooling mode.
"HEAT" Speed - cfm
A
B
C
1
1150
1035
690
1000
900
600
1000
900
600
"HEAT" Speed - cfm
A
B
C
1
1495
1380
1150
1300
1250
1000
1300
1200
1000
"HEAT" Speed - cfm
A
B
C
1
2070
1840
1610
1800
1600
1400
1800
1600
1400
"HEAT" Speed - cfm
A
B
C
1
2300
2070
1840
2000
1800
1600
2000
1800
1600
Page 28
"CONTINUOUS FAN" Speed - cfm
D
A
B
690
550
440
600
500
400
600
450
360
"CONTINUOUS FAN" Speed - cfm
D
A
B
1150
715
660
1000
650
600
1000
585
540
"CONTINUOUS FAN" Speed - cfm
D
A
B
1610
990
880
1400
900
800
1400
810
720
"CONTINUOUS FAN" Speed - cfm
D
A
B
1840
1100
990
1600
1000
900
1600
900
810
C
D
330
220
300
200
270
180
C
D
550
440
500
400
450
360
C
D
770
660
700
600
630
540
C
D
880
770
800
700
720
630

Advertisement

Table of Contents
loading

Table of Contents