The outflow is accomplished through gravity force (natural flow). The outlet hose
should be connected either directly to the main drainage - where a pipette for
odours is anticipated, or water runs directly to a drainage well in the ground,
which has a pipette for odours.
ATTENTION: The outlet hose should not be placed higher than a level (as given for
each appliance's type) from the lower side of the dishwasher's dispenser.
ATTENTION: All electrical work must be carried out by a suitably qualified and
competent person.
The dishwasher operates under specific voltage depending on the type of the
dishwasher.
You should supply the power, depending on the appliance's power reception (the
electrical connection should be made by authorized electricians).
Specifications should be met according to the corresponding parts of DIN, VDE,
D100, the EVU connection terms, the relevant ZH 1/37, chapter 7.2 - as well as the
current specifications for accident prevention.
Respectively, the appliance must be connected to a direct power supply electrical
installation through an HO7 RN-F cable with load relief of the appliance.
The electrical safety of this appliance is ensured only if the protective duct has
been connected and checked properly. The corresponding specifications should
be met at this point (see paragraph 1.5).
In addition, the appliance should include a voltage compensation system. For this
reason, the backside of the appliance has a screw with the indication «voltage
compensation».
Following the electrical connection, the action of the protective duct, the voltage
compensation and the insulation value should be checked according to the
existing provisions of DIN VDE.

1.5.1 Protective duct connection and voltage compensation

27
25
DE - Original
1.4.1 Drainage connection

1.5 Electrical Network connection