SE2000BX Static Exciter

Specifications:

Input Voltage
Output Amperage
Type Regulation
Protection
Physical Size
Weight
Voltage Regulator XR500D
Build up module
Build up voltage
P.O. Box 291509 Kerrville, Texas USA 78029-1509 Phone: 830.895.4700
Fax: 830.895.4703 Email:
Rev 3
The SE2000BX Static Exciter is designed to
replace most electronic, saturable reactor and
rotary exciters used on slip ring or rotor fed
electric generators. The SE2000BX offers
unique features such as a remote mounted
control panel and easy serviceability in the
field. The input power and voltage sensing
for the SE2000BX are taken directly from the
generator AC stator and rectified into a
controllable DC input to the main generator
rotor. The SE2000BX is a complete static
exciter that includes the voltage regulator,
power fusing, surge suppression, build up
module and connection terminals. Optional
devices are offered for the SE2000BX such
as an interface card, which allows the
SE2000BX to be controlled with power factor
controllers and other types of genset and PLC
controllers. The SE2000BX has provisions
for parallel operation.
190 to 250vac, single phase
200adc continuous
Flat response/VPH
Internal fusing
24 x 30 x 12 in
50 lbs
AFM500X
6.5vac
pti@power-tronics.com
Internet: www.power-tronics.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SE2000BX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Power-Tronics SE2000BX

  • Page 1 The input power and voltage sensing for the SE2000BX are taken directly from the generator AC stator and rectified into a controllable DC input to the main generator rotor.
  • Page 2 The SE2000BX is designed for simple installation and the voltage regulator assembly is designed so that it can be remotely located for safety and operator convenience. The SE2000BX should be located in a dry and clean area with free airflow over the rectifier section.
  • Page 3 Figure A Main power input and field wiring diagram Safety Disconnect Switch 240vac from generator SE2000BX F+ to main rotor F- to main rotor Removable Control Panel P.O. Box 291509 Kerrville, Texas USA 78029-1509 Phone: 830.895.4700 Fax: 830.895.4703 Email: pti@power-tronics.com...
  • Page 4 Figure B Control Wiring* *The SE2000BX static exciter has a removable control panel located below the main rectifier assembly. It is recommended that this panel be mounted in a location away from the main exciter assembly for safety and operator use. The relocation should be as close to the exciter assembly as possible.
  • Page 5 Figure C *Additional Hookup connections for parallel operation of the SE2000BX * Optional, must be ordered on original specifications. 5 amp CT Droop Adjustment GENERATOR 6Ω, 100w 240vac Unit / Parallel Switch SE2000BX Generator voltage should droop during starting of an inductive load, if it rises, reverse the X and Y connections.
  • Page 6 PLC. Refer to the UIC200 instruction manual for complete details. P.O. Box 291509 Kerrville, Texas USA 78029-1509 Phone: 830.895.4700 Fax: 830.895.4703 Email: pti@power-tronics.com Internet: www.power-tronics.com...
  • Page 7 Power-Tronics, Inc., warranties only parts and workmanship of this product for a period of 2 years from the original date of purchase from Power-Tronics, Inc. Under warranty, Power-Tronics, Inc. will replace, exchange or repair the defective product without labor or parts cost to the customer.

Table of Contents