Tee Cap (Tc); Drain Tee Cap (Dtc) - M&G DuraVent DuraStack PRO DCL Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

TEE CAP (TC)

The Tee Cap provides access for cleaning and inspection into the chimney. Usually on
horizontal runs, the Tee Cap is used to close the unused port of any Tee and for cleanout
or access purposes only. When using clean-outs, always seal the connection to prevent
leaks and assure that the chimney functions as intended.
The part list includes;
1x Cap with one Handle
1x smaller V-Band (BSI)
The Next Item are for Models DIS PRO / DAS PRO only:
- 1x Outer Casing;
- 1x Insulation Band for Models DIS1 or DIS2;
1 or 2x insulation band for Model DIS4
- 1x Insulation Pad for DIS1 or DIS2, or 2x Insulation pad for DIS4
- 1x Larger inner V-Band (BSI)
INSTALLATION PROCEDURES
1 - Apply sealant to duct flue flange and on the Inner Cap (disc with one handle), about
a 3/8" bead all around the cap.
Figure 33a: Step 1 for the installation of the TC
2 - Use the smaller inner V-Band (BSI) to secure the cap to the flange of the 90° Tee
(T90, not included) as specified in the JOINT ASSEMBLY section
NOTE: Be sure the handle of the cap faces outward as shown. See Figure 33b
Figure 33b: Tee Cap Step 2
17
THE NEXT STEPS ARE FOR MODELS DIS PRO / DAS PRO ONLY.
3 - Then add the insulation pad at the bottom of the casing.
4 - Wrap the insulation band around the inner wall of the Tee, up to the spacer/brackets
inside the Tee. See Figure 33c.
Figure 33c: Tee Cap insulated casing Step 3 and 4
5 - Mate the flange of the outer casing with the flange of the out wall of the Tee section.
For a proper installation, make sure that the insulation band goes up to the
spacers of the T90.
6 - Secure with the bigger V-band (BSI) by tightening the retaining screw. See Figure
33d
Figure 33d: Tee Cap insulated casing Step 5 and 6

DRAIN TEE CAP (DTC)

The Drain Cap (DTC) is used as a drain for the base of vertical installation and must be
connected to a suitable disposable point. It can also be used as an access for cleanouts
or access purpose. See Figure 34. Same installation as a Tee Cap (TC).
Figure 34: Drain Tee Cap (DTC)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.