Ventilation System - Viking VMOR506 Installation Manual

Convection microwave hood
Hide thumbs Also See for VMOR506:
Table of Contents

Advertisement

Available languages

Available languages

Ventilation System

This Convection Microwave Hood is designed for
adaptation to three types of hood ventilation systems.
Select the type required for your installation.
RECIRCULATING — non-vented, ductless.
Follow installation procedure (A). Recirculating requires
the use of the Charcoal Filter, which has been installed
in the oven.
HORIZONTAL EXHAUST — outside ventilation.
Follow installation procedure (B).
VERTICAL EXHAUST — outside ventilation.
Follow installation procedure (C).
(A) Recirculating: Non-vented,
Ductless Operation
• The unit is shipped assembled for recirculating.
• The Exhaust Damper Assembly is NOT REQUIRED for
recirculating exhaust.
• Charcoal Filter, included with the unit, IS REQUIRED
for recirculating exhaust.
(B) Horizontal Exhaust: Outside
Ventilation
HORIZONTAL EXHAUST: Remove and save 4 screws.
Remove fan cover bracket.
(Preparing Oven for Installation)
Fan Cover
Bracket
HORIZONTAL EXHAUST: Withdraw hood fan unit
carefully and slip wires out of wire box.
HORIZONTAL EXHAUST: Rotate hood fan unit 180˚ so
that exhaust ports are facing rear of oven unit.
• CAUTION: Do not pull or stretch hood fan wiring.
• Replace hood fan unit into the oven unit. Be careful
not to pinch the lead wire between the inner bracket
and the hood fan unit.
• Put the lead wire into wire box.
E4
Hood Fan
Unit
Hood Fan
Unit