    THIS NOTICE MUST BE GIVEN TO THE POOL OWNER PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE PARTS INCLUDED IN THE DELIVERY Roll-Energy evolution (2 boxes - Supports + Tube) Template Anodised aluminium tube with tubular motor Sleeve Sleeve Washer Allen key Ø8...
  • Page 3: Packing List

    Aluminium beam Middle telescopic support “Model according to your order” (1 box) (1 box) «OPTION» Hanging and surface Insert mount mount support (for pool width > to 6 m) Decking “Model according to your order” (1 pallet) Exotic wood IPE NECESSARY TOOLS - (INSTALLATION - 2 PERSONS) PACKING LIST example - for a 5 x 10 m pool with Ø3 m step unit...
  • Page 4 INFORMATION For concrete, cellular concrete, full or hollow masonry pools, positioning is identical on the motor side and the free side. For polyester and panel pools, forecast concrete reinforcement for the installation of the supports and safety locking kits. Quantity of concrete (in litres ) necessary for the supports reinforcement : Pool surface (m²) x 2.5 = x concrete litres Open pool : the cover is in the cover pit under the decking.
  • Page 5 THE IN GROUND COVER Tubular motor con- form to slats Decking electrical standards Gap between the wall and the cover Safety wall or Sécuriwall Control box conform to Switch with maintained contact electrical standards : during locking looking at the pool C 15-100 NF EN 60335 OPTION...
  • Page 6 CHARACTERISTICS AND COVER PIT DIMENSIONS The sides of the cover pit must be vertical and parallel between them. L = Pool length (step unit and cover pit) skimmer Concrete separation wall Minimum distance of the cover pit water level regulator Main drain L = Pool length (step unit and cover pit) skimmer...
  • Page 7 TEMPLATE Straight radius C + 25 mm C - 25 mm with coping stone Middle of the template Radius or cut sides C + 25 mm C - 25 mm - Fit the template and mark the position of the drill holes.
  • Page 8 SETTLEMENT OF THE SUPPORTS Do not forget the hole to join the motor’s electrical cable and the connection box. (page 14) Fixation en façade Fixation cavalier “OPTION” Washer Washer Sleeve Screw Sleeve Screw Ø8,4x15 Ø8,4x24 Ø12 M8x80 Ø12 M8x80 Ø12 Ø12 Concrete Concrete blocks...
  • Page 9 TUBE INSTALLATION ON THE SUPPORTS Motor side : Passing the cable through the motor moteur cable side plate. Washer Ø8,4 x 24 Free side : Push the tube so that the motor side is fitted properly against the wall. Washer Ø8,4 x 24 Tightening ring Allen key...
  • Page 10 Adjustable hanging mounted model Screw inox A4 For concrete or panel pools M10 x 60 Washer Hanging support Ø10 Ø12 Sleeve Nut Inox A4 M10 Ø12 Align the beam support with the separating wall Panel settlement : Washer Ø8 Nut M8 Screw Cover pit M8 x 20...
  • Page 11 Surface mounted model For concrete or panel pools and pools with a wall thicker than 8mm Sleeve 12 x 60 Align the beam support with the separating wall Washer Ø8.4 x 24 Cover pit Screw TH M8 x 80 Concrete Concrete blocks Washer Washer...
  • Page 12: Cover Installation

    COVER INSTALLATION Install the slats on the water and clip them together. Take care with the direction Allen Key of the cover over the pool mâle n°4 Cut out female male down Fit the slats along “CLAC” the whole length Repeated wiggling/handling of the slats may be needed..
  • Page 13 ALUMINIUM BEAM INSTALLATION Cover pit side Middle telescopic support OPTION MIDDLE TELESCOPIC SUPPORT 900 maxi For pool over 6 m wide, you need to install 1 or 2 middle telescopic support, to maintain the beam. WEIGHT INSTALLATION Weights guarantee a better reeling of the cover around the tube and guide the cover. The weight for the step unit prevents the slats from falling behind the cover pit.
  • Page 14 ADJUSTMENT OF THE WEIGHT DEPTH Adjust the depth of the weight 5 cm Closed pool Open pool...
  • Page 15 DECKING INSTALLATION Seal for wooden decking...
  • Page 16 ELECTRICAL WIRING / WI-KEY The installation must comply with the C15-100 standards (last version). Installation in a dry, airy and moderate local. a* : Wire present or not depending on the motor type Circuit breaker with a 30 mA protection. Salt electrolysis system Connection...
  • Page 17 WI-KEY INSTALLING THE CONTROL BOX red / green flashing = emitter locked Emitter unlocking procedure see «page 30» The emitter must be located outside volume 0. The distance between the emitter and the receiver must not exceed: - 50 m in an obstacle-free zone. - 25 m behind a basic wall.
  • Page 18 ELECTRICAL WIRING WITH KEY OPERATED BOX The installation must comply with the C15-100 standards (last version). Installation in a dry, airy and moderate local. a* : Wire present or not depending on the motor type Circuit breaker with a 30 mA protection.
  • Page 19 AUTOMATIC STOP ADJUSTMENT (MOTOR DL6010-DL7710) 1 - Programme starting : check up Cover closing Contact maintained Cover opening if the control logic is incorrect, Check the wiring installation Cover installation «open pool» Adjust the position of the cover using the programme «open and closed» Be careful to choose the right position, it will be the starting reference.
  • Page 20 Cover installation «closed pool» Adjust the position of the cover using the programme «open and closed» Be careful : the last operation used must be a closing. «if you cannot close the cover, chek the electric control is correct and start the automatic stop adjustement procedure from the deginning. » Recording position «closed pool»...
  • Page 21 TORQUE LIMITER DEVICE The torque limiter device protects the system in case locking kits are unreleased during the opening. In the event of excessive resistance during opennig the sotor is automatically stoppedt. Cases of torque limiter activation : - Unreleased safety locking kit. - cover rudding (coping stone...) - Object wedged on / under the cover (cleaner ...).
  • Page 22 CARD ADJUSTMENT (SWITCH REGLAGE) 1 2 3 4 CONTROL TIME ADJUSTMENT (SWITCH REGLAGE) = pool length step unit included L > 12 m L <= 12 m 1 2 3 4 1 2 3 4 60 seconds 30 seconds ADJUSTEMENT OF THE SENSITIVITY (SWITCH PROG) = pool width <= 3 m <= 4 m...
  • Page 23 LOCKING KITS The position of the fastener kits on the cover is indicated on the drawings shipped with the slats. All changes to the positioning of the kits must comply with the rules given below. For other cases please contact us. Positioning rules With With side...
  • Page 24 PUSH-LOCK INSTALLATION A water level regulator is mandatory Insert mounted model Inserted For concrete and panel pools part Hollow white Ø16 washer 5 cm mini VBA TF Z pozi stainless steel A4 Ø6 x 60 wood screw Acceptable limit of level variation 50 mm water level...
  • Page 25 INSTALLATION QUICK-LOCK A water level regulator is mandatory Insert mounted model Inserted For concrete and panel pools part Hollow white Ø16 washer VBA TF Z pozi 5 cm stainless steel A4 Ø6 mini x 60 wood screw adjustement Acceptable limit of level variation 5 cm water level...
  • Page 26 INSTALLATION PASSE-SANGLE A water level regulator is mandatory Insert mounted model Inserted For concrete and panel pools part Hollow white 5 cm Ø16 washer mini VBA TF Z pozi stainless steel A4 Ø6 x 60 wood screw Acceptable limit of level variation 5 cm water level...
  • Page 27 INSTALLATION OF THE STRAP-HOLDER ANCHOR EYEBOLT Eyebolt for concrete beach The head of the eyebolt must be higher than the beach surface between Ø20 25 et 40 cm depth : 5 cm Do not force the eyebolt into a drill hole of a smaller diameter than this Eyebolt for wooden beach Centre of the straplock...
  • Page 29: Light Indicators

    ALWAYS KEEP AN EYE ON THE POOL DURING OPENING OR CLOSING OPERATIONS. ALWAYS CHECK THAT THE POOL WATER LEVEL IS CONSTANT AND COMPLIANT WITH THE RECOMMENDATIONS ON THE INSTRUCTIONS - It is imperative not to halt the cover in an intermediate position, this can cause the risk of jamming a bather’s body under the cover casing, if a bather uses the pool.
  • Page 30 Locking Releasing Locking check the system is with tool locked Releasing with tool The cover must not exit the Quick Lock before you activate the key switch.
  • Page 31 Locking Install the strap between the wall and The strap must the bracket be under ten- sion and must be through the bracket Lock the anchor Releasing Remove the strap from around the bracket and put it on the cover Release the anchor...
  • Page 32 1 - In the event of an explained stoppage during opening : (unreleased locking kits or other...) - Closed the cover for more than 3 seconds, until the tension of the cover is completely released. (closed the cover for more than 3 seconds until the tension of the cover is completely released) - Remove causes of stoppage, e.g.
  • Page 33 (eg. somebody falling) - Check the straps connecting the cover to the roller / tube. - Apply twice a year a «wood saturator or a treatment oil» (see catalogue DEL), on IPE and beech deckings. - All work must be carried out by your installer who will contact the manufacturer if necessary.
  • Page 34: Replacing The Batteries

    - Close the cover and prepare the pool for winter, without lowering the water level. - If you need to lower the water level, reel-in the cover around the tube and use a winter cover. - We recommend you install the IVERNEA winter shield to protect the cover from UVs and dirt Pairing -- delivered pre-paired receiver...