CONTENTS PLEASE READ THESE INSTRUCTIONS CAREFULLY AND KEEP THEM FOR FUTURE REFERENCE Please read this manual carefully to help you understand all of the information and to ensure safe installation, use and servicing. We are not held liable for any damage arising due to a failure to respect the instructions set out in this manual.
Page 3
CONTENTS Installation of the counterweights ................p. 17 Installing the decking .....................p. 17 Wiring for MIT 1210-3210 control box with Wi-Key control ........p. 19 Wiring for MIT 1210-3210 control box with key switch ..........p. 20 Wi-Key ..........................p. 22 Settings ...........................p. 25 SERVICING/MAINTENANCE ....................p.
DESCRIPTION COMPONENTS PROVIDED PLATE Template template Plate Ø8.4 Washer Ø12 x 24 Sleeve M8x80 Screw Washer Sleeve Bag of loose fittings CONTROL BOX AND COVER CONTROL Control insert mount key switch Wi-Key key switch emitter OPTION Junction box...
Page 5
DESCRIPTION COUNTERWEIGHTS REEL SYSTEM Counterweight Allen key Quantity depending male No.4 on width of pool Anodised aluminium reel system with tubular motor BEAM SUPPORTS – Model and colour according to order (1 Packing) Adjustable Pegged hanging insert mount façade mount BEAM –...
DESCRIPTION TOOLS REQUIRED FOR ASSEMBLY PACKING LIST ASSEMBLY Example – for a 5.00 x 10.00m pool with roman stairs Plates+control box: 1 0.65 x 0.45 x 0.25/40kg Packing 2 persons Reel system: 1 0.15 x 0.15 x 5.10 m/40kg Packing Beam: 1 0.15 x 0.15 x 5.10m/34kg Packing Beam support: 1 0.30 x 0.20 x 0.20m/10kg Packing 3 hours...
15cm max. 4cm min. • On mirror or infinity pools, DEL covers do not comply with French standard NF P90- 308 unless the pool is equipped with a Vitalia INFINITY control box to automatically lower the water level by at least 2cm when the pool cover is closed.
INSTALLATION CHARACTERISTICS AND VERIFICATION OF THE INTERNAL DIMENSIONS FOR COVER PIT The walls of the housing must be vertical and parallel with each other. L = pool length (including stairs and housing) Skimmer 40 min. 150 max. 50 min. I = minimum internal Separating wall dimension of...
Page 9
INSTALLATION < 6 (in m) to 7 to 8 to 9 to 10 to 11 to 12 to 13 to 14 to 15 to 16 to 17 (in mm) Decking Decking 750mm 900mm (in m) to 18 to 19 to 20 to 21 to 22 to 23...
INSTALLATION TEMPLATE RIGHT ANGLE C - 25 mm C + 25 mm with rim water Centre of template SHELVES OR CUT-OFF CORNER WITH BRICK SEPARATING WALL C + 25 mm C - 25 mm water Centre of template • Carry out the Template for both sides of the pit. •...
INSTALLATION RIGHT ANGLE OR SHELVES OR CUT-OFF CORNERS WITH SÉCURIWALL C - 25 mm C + 25 mm water Centre of template Sécuriwall • Carry out the Template for both sides of the pit. • The deck fastenings must be above the water level. DRILLING Ø12 80mm minimum...
Page 12
INSTALLATION FASTENING THE DECKS Remember to leave room for the motor cable to go to the Junction box. FAÇADE FASTENING HANGING MOUNT FASTENING AS AN OPTION Ø8.4 Bolt Ø12 Ø12 M8x80 Ø8,4 x 15 Washer M8 x 90 x 24 Sleeve Sleeve Screw...
INSTALLATION INSTALLATION OF THE REEL SYSTEM • Do not carry the reel system Motor side by holding the motor cable • If there is water in the pool, let the reel system fill up with water. • Test the motor before launching.
INSTALLATION ENSURE THAT THE REEL SYSTEM/POOL ARE PERPENDICULAR Calibration Motor side ENSURE THAT THE REEL SYSTEM/POOL ARE PERPENDICULAR 90° Free side To allow the cover to be rolled out, it is essential for the reel system to placed perpen- dicular to the length of the pool. BEAM SUPPORT ADJUSTABLE HANGING MOUNT VERSION TF M8x60...
Page 15
INSTALLATION VERSION INSERT MOUNT For concrete pools Joint 1 Joint 2 Box insert Bolt mount Liner Flange Stick joint 1 onto the housing before installing the liner. Place joint 2, the flange and bolt into place. Cut the liner using a Stanley knife. PEGGED FAÇADE VERSION For concrete block and concrete pools, as well as pools Universal Sleeve 12...
INSTALLATION INSTALLING THE BEAM Pool cover housing side MIDDLE TELESCOPIC SUPPORT For pools that are more than 6m wide, remember to install 1 or 2 intermediate Beam supports in order to support the centre of the beam (see enclosed leaflet). INSTALLING THE COUNTERWEIGHTS The counterweights ensure that the cover is rolled up correctly by “holding”...
Dimensions must be determined in compliance with the applicable standard. If the decking are not supplied by DEL, you are responsible for their compliance. The use of decking that do not comply with the standard will de facto render the entirety of the installation non-compliant.
Page 18
INSTALLATION ELECTRICAL CONTROL BOX MOUNTING THE CONTROL BOX • The control box must be fixed to the wall of the equipment room in an easily accessible position, between 1 metre and 1.80 metres above the floor. • The box must be securely fixed to the wall using the screws and plugs supplied with it. •...
INSTALLATION CONTROL BOX The electrical connection of the equipment must only be carried out by a qualified professional, and they must comply with the manufacturer’s instructions in addition to the following applicable standards and regulations: - NF C15-100: Low voltage electrical installations. - CEI 60364: Electrical installations for buildings.
INSTALLATION WIRING FOR MIT 1210-3210 CONTROL BOX WITH WI-KEY CONTROL * see comments and diagrams on page 21 *Filtration housing contactor 230 V contactor limit switch cable Stop flow 3 x 1,5 mm motor cable 30mA residual circuit breaker Connection Socket 230 Volts Single-phase 50Hz...
Page 21
INSTALLATION WIRING FOR MIT 1210-3210 CONTROL BOX WITH INSERT MOUNT KEY SWITCH CONTROL * see comments and diagrams on page 21 *Filtration housing contactor 230 V contactor limit switch cable Stop flow 3 x 1.5 mm motor cable 30mA residual circuit breaker Connection Socket 230 Volts...
Page 22
INSTALLATION * “PUMP” terminal block Piloting the filtration pump. When the cover is moving: Contact C-NO open (stop filtration) and contact C-NC closed (filtration). BEFORE AFTER ** “SALT” terminal block electrolyser control From 80% closed: Contact C-NO closed and contact C-NC open From 20% open: Contact C-NO open and contact C-NC closed The position of the dry contact is saved in the memory in case power to the control box is ever switched off.
INSTALLATION WI-KEY CONTROL Flashing red/green = emitter locked See emitter unlocking procedure page 24 Emitter Receiver Manufacturer Reference Wi-Key receiver Wi-Key emitter Category 3 (NF EN 300220-1) 3 (NF 300220-1) 50m open field range 50m open field range Range 25m through a concrete 25m through a concrete wall wall...
Page 24
INSTALLATION • It must be located in a place that allows the operator to check that no-one is in the pool during the operation. • It is compulsory for the locking “bar” to be installed and bolted into place. • Before fastening the control box, ensure that the emitter is communicating with the receiver.
Page 25
INSTALLATION Emitter Press “STOP” and hold the switch down, then press “O” for more than 3 seconds OK when the indicator flashes red/green Indicator light STOP Connection of a new emitter must be carried out within the following 30 seconds. LOCK WI-KEY •...
INSTALLATION Any person carrying out work on the electrical parts must be qualified and wear PPE (personal protective equipment): gloves, goggles, mat, etc… Warning: use of the pool cover control switchs present in the housing (Wi-Key receiver) must only be carried out by a person who is absolutely certain that there is no risk and that no-one will enter the pool during the operation.
Page 27
INSTALLATION PROGRAMMING THE TORQUE LIMITER (AUTOMATIC SWITCH) The automatic switch protects the system from any potential oversights with regard to the unlocking of the fastening control boxs, when the pool is opened. If the cover is blocked, the motor will stop automatically. The different reasons for a blockage: •...
Page 28
INSTALLATION LED SIGNALLING Initialisation (Red LED green LED and orange LED flash alternately). Signal from sensor (motor working, regular slow flashing). Lit and not flashing = Problem with sensor (check the connections and cables). Lit and not flashing = Problem with the software (reprogramme the limit switches). Lit and not flashing = Control of over-torque.
SERVICING/MAINTENANCE Any person carrying out work on the electrical parts must be qualified and they must comply with the manufacturer’s instructions in addition to the applicable standards and regulations. During any intervention, the technician must wear PPE (personal protective equip- ment): gloves, goggles, mat, etc…...
CARE / MAINTENANCE CARE (responsibility of the customer) • Clean your slatted cover thoroughly twice a year (when opening the pool for the season and when winterising it). This is even more important if your pool water is hard. To do this, use a descaling cleaner (see catalogue) and rinse with a water spray. •...
Page 31
SERVICING/MAINTENANCE MAINTENANCE (ONCE PER YEAR MINIMUM) • All interventions must be carried out by a professional, who will contact the manufacturer if necessary (contact details on the back page of this document). • All spare parts must come from the manufacturer or comply with standard NF P90- 308.
Page 32
REPAIR • Do not hesitate to ask our authorised distributors for advice. • If the power cable is damaged, it must be replaced: by the manufacturer, its after- sales service or similarly qualified persons in order to avoid danger.
SERVICING/MAINTENANCE WINTERING • Position the cover in the closed position and keep the water level constant in accordance with the manufacturer's recommendations. Between 7 and 15 cm • During the winter season, in the event of snowfall, it is essential to remove snow from the roof using a brush with a telescopic handle.
SAFETY ADVICE Please read the recommendations set out below with care. WARNING Swimming pools can represent a serious danger for your children. Drowning can happen very quickly. Children who are close to a swimming pool need to be watched constantly and actively, even if they know how to swim.
Page 35
SAFETY ADVICE • This section is by no means a replacement for common sense or individual responsibility. Its aim is not to replace the vigilance of parents and/or responsible adults, who remain the essential factor in ensuring the protection of young children. •...
RECYCLING PACKAGING Dispose of the packaging in line with current rules and regulations. END OF LIFECYCLE • Do not put your scrapped equipment or used batteries in with unsorted household waste. • You are responsible for disposing of all of your waste, in particular electrical and electronic equipment by taking it to a collection point where recycling and valorisation are carried out.