  • Page 1 A U T O M AT I C S A F E T Y C O V E R F O R A B O V E G R O U N D P O O L S CONTURA TECHNICAL INSTRUCTIONS...
  • Page 2 NOTICE TO BE GIVEN TO THE USER AFTER INSTALLATION IS COMPLETE PLEASE READ CAREFULLY AND KEEP IN A SAFE PLACE. Automatic above ground pool motorised roller using either mains electricity or solar power. The opening or closure operation requires about 2 minutes for one person and about 3 minutes to lock or unlock the attachment kits.
  • Page 3 The roller: 42 cm at the shaft 42 cm at the shaft 66 cm 66 cm 55 cm 30 cm 55 cm 30 cm - The motor (compliant with electric standards) is located in the tube and can be accessed from the terminal fitted. - Mechanical or electronic “automatic stop depending on the model”...
  • Page 4: Delivered Parts

    DELIVERED PARTS Option Wi-Key 20.3 Ah 12 V 6.5 Ah 12 V 8.5 Ah 12 V OPTION - CHLORINE INHIBITOR PL3210 Aqua 9...
  • Page 5: Packing List

    TOOLS nr.10 nr.13 nr.17 Ø8 - 12 - 20 ASSEMBLY INSTRUCTIONS PACKING LIST e.g. - for a 4 x 8 m pool 1 0.80 x 0.60 x 1 m pallet —- 55kg 1 4.30 x 0.20 m pack —– 25 kg 4 5 x 0.25 x 0.20 m packs —–...
  • Page 6: Instructions Before Installation

    Instructions before installation SOLAR version Place the solar panel on the sunniest side MAINS version D + 11 cm Remember to have a sheath fitted to connect the electric control box and see positioning the motor terminal. rules (page 8) D = (measurement between the terminal - pool width) / 2 PL3210...
  • Page 7 Assembling the roller Contura removable motorisation motor side Contura fixed motorisation motor side...
  • Page 8 Position of the roller on the pool Position 1 Depending on the pool corners and the fastener kits on the roller side Rounded corners or cut-off corners Sharp corner Max = 60 cm With straplock Push-lock Min = 15 cm Min = 15 cm Max = 60 cm With...
  • Page 9 Position 2 centre of the width Contura removable motorisation motor side 5 mm 5 mm Contura fixed motorisation motor side 5 mm...
  • Page 10 Levelling ground Before fixing, check that there is an operating gap of 5 mm on each side. (see “positioning 2” previous page) nr.17 Ø12 Fix the adjustment bar 5 mm...
  • Page 11: Installing The Motor

    INSTALLING THE MOTOR Contura removable motorisation № Make small rotating movements with the motor to ease its fitting.
  • Page 12 WIRING - CONTURA SOLAR - VERSION WITH REMOVABLE MOTORISATION / WI-KEY C O F...
  • Page 13 WIRING - CONTURA MAINS - WITH REMOVABLE MOTORISATION / WI-KEY The electric control box must be fitted in a dry room. The installation must comply with the NF C15-100 standard and CEI 60364 (Last applicable version) ask your electrician for advice or contact...
  • Page 14 WIRING - CONTURA SOLAR - VERSION WITH REMOVABLE MOTORISATION / KEY SWITCH...
  • Page 15 WIRING - CONTURA MAINS - WITH REMOVABLE MOTORISATION / KEY SWITCH The electric control box must be fitted in a dry room. The installation must comply with the NF C15-100 standard and CEI 60364 (Last applicable version) ask your electrician for advice or contact...
  • Page 16 WIRING - CONTURA MAINS - WITH FIXED MOTORISATION / WI-KEY The electric control box must be fitted in a dry room. The installation must comply with the NF C15-100 standard and CEI 60364 (Last applicable version) ask your electrician for advice or contact your electricity provider.
  • Page 17 WIRING - CONTURA MAINS - WITH FIXED MOTORISATION / KEY SWITCH The electric control box must be fitted in a dry room. The installation must comply with the NF C15-100 standard and CEI 60364 (Last applicable version) ask your electrician for advice or contact your electricity provider.
  • Page 18: Cover Installation

    COVER INSTALLATION Make sure the slats are in the right direction Roller water 35 cm If necessary, cut the sides to ease skid the passage of the strap cover and avoid rubbing Slat assembly By clipping “CLICK” along the whole length of the slat Repeat the movement until all the slats are completely clipped together By sliding...
  • Page 19 Assembly of the strap between the cover and the tube The surface to be glued must be clean and notch skid assembly The skids are used to orient the cover at the start of closure. The holes are drilled at the factory.
  • Page 20 WI-KEY INSTALLING THE CONTROL BOX red / green flashing = emitter locked Emitter unlocking procedure see «page 29» The emitter must be located outside volume 0. The distance between the emitter and the receiver must not exceed: - 50 m in an obstacle-free zone. - 25 m behind a basic wall.
  • Page 21 ADJUST THE AUTOMATIC STOPS 1 - Contura removable motor version Les flèches, indiquent le sens de déplacement du tablier En tournant dans le sens +, vous augmentez la plage de déplacement du tablier En tournant avec dans le sens -, vous réduisez la plage de déplacement du tablier...
  • Page 22 Adjust the automatic stops 1 - Start programming: 2 - Cover “pool open” position Adjust the cover position using the 2 “open and close” commands 3 - Memorise the “pool open” position 4 - Cover “pool closed” position Adjust the cover position using the 2 “open and close”...
  • Page 23 Pilot Pool opening maintained contact Pilot Pool closure If the command logic is not correct, check the installation wiring. Setting the roller model Contura removable Contura fixed motorisation motorisation Setting control duration L <= 12 m L > 12 m...
  • Page 24 Adjusting the trigger sensitivity Maximum sensitivity SWITCH PROG <= 3 m <= 4 m <= 5 m <= 6 m <= 7 m <= 8 m <= 9 m <= 10 m Minimum sensitivity Activating the automatic switch Failure to activate the automatic switch can cause serious damage to the motor, the control box, the activated slats and void the warranty.
  • Page 25 CLOSE THE TERMINALS LOCKING KITS The position of the fastener kits on the cover is indicated on the drawings shipped with the slats. All changes to the positioning of the kits must comply with the rules given below. For other cases please contact us. Positioning rules With With side...
  • Page 26 PUSH-LOCK INSTALLATION A water level regulator is mandatory Insert mounted model For concrete and panel pools Inserted part Hollow white Ø16 washer 5 cm mini VBA TF Torx stainless steel A4 Ø6 x 50 wood screw Acceptable limit of level variation 50 mm water level recommended...
  • Page 27 INSTALLATION QUICK-LOCK A water level regulator is mandatory Insert mounted model Inserted For concrete and panel pools part Hollow white Ø16 washer VBA TF Torx 5 cm stainless steel A4 Ø6 mini x 50 wood screw adjustement Acceptable limit of level variation 5 cm water level...
  • Page 28 INSTALLATION PASSE-SANGLE A water level regulator is mandatory Insert mounted model Inserted For concrete and panel pools part Hollow white 5 cm Ø16 washer mini VBA TF Torx stainless steel A4 Ø6 x 50 wood screw Acceptable limit of level variation 5 cm water level recommended...
  • Page 29 INSTALLATION OF THE STRAP-HOLDER ANCHOR EYEBOLT Eyebolt for concrete beach The head of the eyebolt must be higher than the beach surface between Ø20 25 et 40 cm depth : 5 cm Do not force the eyebolt into a drill hole of a smaller diameter than this Eyebolt for wooden beach Centre of the straplock...
  • Page 30 ALWAYS KEEP AN EYE ON THE POOL DURING OPENING OR CLOSING OPERATIONS. ALWAYS CHECK THAT THE POOL WATER LEVEL IS CONSTANT AND COMPLIANT WITH THE RECOMMENDATIONS ON THE INSTRUCTIONS - It is imperative not to halt the cover in an intermediate position, this can cause the risk of jamming a bather’s body under the cover casing, if a bather uses the pool.
  • Page 31 Locking Releasing...
  • Page 32 Locking check that the system with the tool has kicked in Releasing with the tool the cover must not come out of the Quick-lock until the key switch has been turned (risk of re-triggering) Locking Pass the strap The strap must between the side and be tight the straplock rod...
  • Page 33 - To ensure optimum safety and the correct operation of the roller, always check that the level of the water in the pool remains constant and compliant with the manufacturer’s recommendations. (For further comfort, use an overflow and a level regulator). - When the level is too high it is caused by the overflow being blocked by leaves or other debris.
  • Page 34: Replacing The Batteries

    In the event of a motor or electric failure, you can remove the motor to close the pool manually. 1 - Cut the electricity supply 2 - Disconnect the motor 3 - Remove the fixtures and remove the motor 4 - Unroll the cover manually. 5 - Place the fastener kits.
  • Page 35 1 - Stop due to an actual jam: (unreleased locking kits or other...) - Close the cover for more than 3 seconds, until the tension of the cover is completely released. (The next opening will remain protected by the system) - Remove causes of jamming, and resume opening the pool.
  • Page 36 Dear customers, Thank you for choosing a DEL automatic cover. Please read the instructions below carefully. ·Pools can be a serious danger for children. Drowning can happen quickly. S A F E T Y A D V I C E When children are around the pool this requires your constant vigilance and active supervi- sion, even if they can swim.