Summary of Contents for HAMPTON BAY GAZEBO YG188-BN
Page 1
USE AND CARE GUIDE GAZEBO II 52 IN. CEILING FAN Questions, problems, missing parts? Before returning to the store, call Hampton Bay Customer Service 8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST Saturday 1-855-HD-HAMPTON HAMPTONBAY.COM...
Safety Information To reduce the risk of electric shock, ensure electricity has However, there is no guarantee that interference will not occur been turned off at the circuit breaker or fuse box before in a particular installation. If this equipment does cause harmful beginning.
Warranty We warrant the fan motor to be free from defects in workmanship and material present at time of shipment from the factory for a period of lifetime after the date of purchase by the original purchaser. We also warrant that all other fan parts, excluding any glass or acrylic blades, to be free from defects in workmanship and material at the time of shipment from the factory for a period of two years after the date of purchase by the original purchaser.
Pre-Installation (continued) HARDWARE INCLUDED HARDWARE INCLUDED NOTE: Hardware shown to actual size unless noted otherwise in the table below. Part Part Description Description Quantity Quantity Plastic wire nut Canopy mounting screws with lock washer (preassembled) Blade attachment screw and rubber washer (not to scale) Blade arm screw and lock washer (preassembled) Clevis pin (preassembled) Cotter pin (preassembled)
Pre-Installation (continued) DUAL MOUNTING INSTRUCTIONS DUAL MOUNTING INSTRUCTIONS This ceiling fan is supplied with two types of hanging assemblies: the standard ceiling installation using the downrod with ball and socket mounting, and the "close-to-ceiling" mounting. The "close-to-ceiling" mounting is recommended in rooms with less than 8 ft. ceilings or in areas where additional space is desired from the floor to the fan blades.
Installation MOUNTING OPTIONS MOUNTING OPTIONS NOTE: WARNING: You may need a longer downrod to maintain proper To reduce the risk of fire, electric shock, or blade clearance when installing on a steep, sloped ceiling. personal injury, mount the fan to an outlet box marked The maximum angle allowable is 18°...
Assembly — Standard Ceiling Mounting Preparing the canopy Preparing the motor □ □ Remove the canopy ring (B) from the canopy (C). Remove the cotter pin (FF) and clevis pin (EE), and loosen the two collar setscrews (GG) from the fan □...
Assembly — Close-to-Ceiling Mounting Preparing the canopy Preparing the motor □ □ Remove the canopy ring (B) from the canopy (C). Remove three of the six collar mounting screws with lock washers (HH) (every other one) from the collar □ Remove the mounting bracket (A) from the canopy (C) on top of the fan motor assembly (G).
Assembly — Hanging the Fan Attaching the fan to the electrical box WARNING: To reduce the risk of fire, electric shock or other personal injury, mount the fan only to an outlet box or supporting system marked acceptable for fan support and use the mounting screws provided with the outlet box.
Page 12
Assembly — Hanging the Fan (continued) Making the electrical connections Ground Black White conductor WARNING: To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. WARNING: Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire nuts (except for the ground wire).
Page 13
Assembly — Hanging the Fan (continued) Standard ceiling mounting Close-to-ceiling mounting WARNING: Locking slots of the canopy (C) are provided WARNING: Make sure the tab on the mounting bracket (A) only as an aid to mounting. Do not leave the fan assembly properly sits in the groove in the hanger ball (E) before unattended until all four canopy mounting screw with lock attaching the canopy (C) to the mounting bracket (A) by...
Assembly — Attaching the Fan Blades Removing the rubber Attaching the blades to packing mounts the blade arms □ □ The fan motor assembly (G) is shipped with rubber Attach the blades (H) to the blade arms (I) using the packing mounts (PP) to prevent movement during three blade attachment screws and rubber washers transportation.
Assembly — Installing the Light Kit Attaching the light kit to Installing the light bulb the switch housing and glass shade CAUTION: Before starting installation, disconnect the NOTE: If you do not wish to install the light kit, skip steps power by turning off the circuit breaker or removing the fuse 11 through 12 and proceed to step 13.
Assembly — Installing the Light Kit (continued) Installing the fan without the light kit (Optional) □ Disassemble the switch housing cover (UU) from the light kit (J). You can keep the light kit (J) for future use. □ Attach the plastic plug (LL) to the switch housing cover (UU).
Operation (continued) REVERSE SWITCH OPERATING INSTRUCTIONS REVERSE SWITCH OPERATING INSTRUCTIONS The reverse switch is located on the surface of the switch housing. This switch controls directions: forward (switch down) or reverse (switch up). NOTE: Wait for the fan to stop before reversing the direction of the blade rotation.
Troubleshooting WARNING: Make sure the power is off at the electrical panel box before you attempt any repairs. Refer to step 6 “Making the electrical connections” on page 12. Problem Problem Solution Solution □ Check the main and branch circuit fuses or breakers. The fan will not start.
Service Parts Part Part Description Description Part Part Description Description Mounting bracket (preassembled) Plastic wire nut Canopy ring (preassembled) Canopy mounting screws with lock washer (preassembled) Canopy Blade attachment screw and rubber washer Canopy bottom cover (preassembled) Blade arm screw and lock washer (preassembled) Hanger ball/downrod assembly Clevis pin (preassembled) Coupling cover...
Page 20
Questions, problems, missing parts? Before returning to the store, call Hampton Bay Customer Service 8 a.m. - 7 p.m., EST, Monday-Friday, 9 a.m. - 6 p.m., EST Saturday 1-855-HD-HAMPTON HAMPTONBAY.COM Retain this manual for future use. YG1880001-A...