4 START-UP AND OPERATION

Warning.
• The lithium battery used in this device may present a risk of fire or chemical burns if mistreated. Do
not recharge, disassemble, heat above 100°C or incinerate.
• Replace battery with an ABB supplied part only. Use of another battery may present a risk of fire
or explosion.
• Dispose of used batteries promptly. Keep away from children.
• Dispose of used batteries in accordance with local regulations.
• Where possible, recycle used batteries.
• Contact the local environmental authority for further information regarding disposal or recycling
schemes for used batteries.
Note. Each battery must be connected to the cable from the same side of the termination area as the
battery position.

4.1 Connecting Batteries

The AquaMaster is supplied with one or two batteries, but not connected. To connect see Fig. 4.1.
Note. GSM-equipped transmitters are supplied with the batteries connected but in transportation
mode – refer to the label attached to the equipment.

4.2 Start-up

Remove any plastic film from the AquaMaster light sensitive display window before commencing normal
operation.
When electrical power is connected, or the plastic film is removed from the display window with electrical
power connected, the AquaMaster performs a self-test operation. If successful, 'Pass' is indicated in the
display window.
If the display shows 'Err 1', check the sensor wiring. If the fault is rectified, the transmitter restarts
automatically.
If the display shows 'Err 2 or 3', contact ABB.