ABB AquaMaster IM9 Installation Manual page 18

Electronic commercial water meter
Table of Contents

Advertisement

...3 ELECTRICAL INSTALLATION
1
Fig. 3.14 Sensor Cable Connections (Gland/Conduit, Remote version)
Fig. 3.15 Sensor Cable Connections (Connector, Remote version)
16
7
Note. This arrangement is an option.
CABLE
ABB
1 Brown(BN)
2 Red (RD)
3 Orange (OR)
4 Yellow (YL)
5 Sleeved Ground
6 Blue (BL)
7 Violet (VI)
Caution. With Belden Cable 8777,
ensure that the black wires are not
interchanged and remain with the
associated twisted pair.
Belden 8777
1 Black
2 Green
3 Black
4 Red
5 Sleeved Ground
6 Black
7 White