Durapac 40 Series Instruction Manual

Durapac 40 Series Instruction Manual

Auto 2 speed electric power unit
Hide thumbs Also See for 40 Series:

Advertisement

Quick Links

Instruction Manual
40 Series Auto, 2 Speed Electric Power Unit
Model – PES4024
Maximum Operating Pressure – 700 bar
ABSOLUTE EQUIPMENT PTY LTD – 2/186 Granite Street, GEEBUNG QLD 4034 – Australia
sales@absoluteequipment.com.au
– Phone:
+61 7 3865 4006
– Fax:
+61 7 3102 6288

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 40 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Durapac 40 Series

  • Page 1 Instruction Manual 40 Series Auto, 2 Speed Electric Power Unit Model – PES4024 Maximum Operating Pressure – 700 bar ABSOLUTE EQUIPMENT PTY LTD – 2/186 Granite Street, GEEBUNG QLD 4034 – Australia sales@absoluteequipment.com.au – Phone: +61 7 3865 4006 – Fax:...
  • Page 2: Product Information

    The user must ultimately make the decision regarding suitability of the product for any given task and assume the responsibility of safety for all in the work area. Contact a Durapac representative if you are unsure of your power unit’s suitability for a particular application.
  • Page 3  Hydraulic equipment must only be serviced by a qualified hydraulic technician. For repair service, contact the Durapac authorised service centre in your area. To protect your warranty, use only high quality hydraulic oil CAUTION: ...
  • Page 4: Installation

    4.1 Familiarise yourself with the specifications and illustrations in this owner’s manual. Know your power unit, its limitations and how it operates before attempting to use. Refer to the specification chart below or if in doubt, contact a Durapac representative. Maximum...
  • Page 5: Operation

    To retract the cylinder, press the ↓ button on the remote pendant. Fluid will flow from “B” port of the subplate. 5.4.2 To stop retracting and hold the cylinder, release the ↓button on the remote pendant. PES4024 Electric Power Unit - V1.0 www.durapac.com Page 5 of 9...
  • Page 6: Pressure Adjustment

    Durapac authorised service centre  Damage to hydraulic hoses may not be detected during visual inspections. For this reason, Durapac recommends that hydraulic hoses be replaced on a regular basis  Tighten connections as needed. Use non-hardening pipe thread compound when servicing connections Dirt, sand, etc.
  • Page 7: Changing Hydraulic Fluid

    When not in use, depressurise and disconnect the power unit from the application. 6.4.2 Wipe clean thoroughly and store in a clean, dry environment. Avoid temperature extremes. 6.4.3 Shield power unit with a protective cover. PES4024 Electric Power Unit - V1.0 www.durapac.com Page 7 of 9...
  • Page 8: Troubleshooting

    Externally adjustable relief valve Reset the relief valve to is not correctly set appropriate level  Damaged o-ring Send to a Durapac authorised service centre for repair  Defective control valve Send to a Durapac authorised service centre for repair ...
  • Page 9 Leaking cylinder seals Replace worn seals. Look for excessive contamination or wear. Replace contaminated fluid  Power unit or valve not operating Contact a Durapac authorised correctly service centre for repair  Overload condition Remedy overload condition  Application does not...

This manual is also suitable for:

Pes4024

Table of Contents