Operation - Campbell Hausfeld FP2028999TT Operating Instructions And Parts Manual

Oilless compressors
Table of Contents

Advertisement

Available languages

Available languages

Installation
(Continued)
green (or green and yellow) wire to a
live terminal.
3. Check with a qualified electrician or
serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.
Overheating, short circuiting and fire
damage will result from inadequate
wiring, etc.

Operation

DEFINITION OF TERMS
ON / OFF Switch ( I / O ) - Push switch
to the ON ( I ) position to turn
compressor on. Push switch to the OFF
( O ) position to turn compressor off.
This switch should be in the OFF ( O )
position when connecting /
disconnecting power cord from
electrical outlet or when changing
tools.
ON Position
OFF Position
Figure 3
Pressure Switch (located internally)-
When the compressor is turned ON,
this switch will shut compressor off
automatically when tank pressure
reaches maximum shut-off / cut-out
pressure. If compressor remains on and
air is depleted from tank, this switch
will allow compressor to automatically
restart at the restart / cut-in pressure.
Pressure Gauge - This gauge reads air
pressure in pounds per square inch
(psi) in the compressor tank. Make sure
this gauge reads ZERO BEFORE
changing air tools or disconnecting
hose from outlet.
FP202801, FP202901, FP202897, FP202999DB, FP202999DQ, and FP202899TT
ON/OFF Switch
Never
connect
Drain Valve
Figure 2 - Unit Identification
ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Handle - Designed to move the
compressor.
Drain Valve - This valve is located on
the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.
Figure 4
LUBRICATION
This is an oilless product and DOES
NOT require lubrication to operate.
BEFORE FIRST STARTUP
BREAK-IN PROCEDURE
(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to
repeat.)
1. Turn regulator knob fully clockwise
(to the right) to open air flow.
2. Do not attach a hose or any other
fitting to the compressor.
3. Turn on/off switch to OFF position.
4. Plug in power cord.
5. Turn on/off switch to ON position.
Allow compressor to run for 5
minutes.
6. Turn on/off switch to OFF position.
7. Unplug power cord.
BEFORE EACH STARTUP
OPERATING PROCEDURE
1. Connect air hose to open port
2. Attach the necessary fitting or tool
3. Turn on/off switch to OFF ( O )
4. Plug in power cord.
5a. If using inflation needles/nozzles:
5b. If using tire chuck or tool: Once
6. Operate tool per instructions.
As air is depleted from the tank by use
of a tire chuck, tool, etc., the
compressor will restart automatically at
its preset "cut-in" pressure. When a
tool is being used continuously, the
compressor will cycle on and off
automatically.
3
Handle
Pressure Gauge
Air Outlet
Safety Valve
located below pressure gauge.
to open end of air hose.
position.
Attach air hose with inflation
fitting to the object you are going
to inflate. While holding inflation
fitting firmly in place, turn on/off
switch to ON position. Allow
compressor to inflate the object.
Turn off compressor and remove
inflation fitting.
chuck or tool is attached to air
hose, turn on/off switch to ON
position and allow compressor to
run until it automatically shuts off.
When using tire chuck to inflate
tires, observe gauge reading on
compressor and periodically check
tire pressure with a separate tire
gauge to prevent overinflation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp202901Fp202897Fp202999dbFp202999dqFp202801

Table of Contents