GFA-OOT
Attaching a Fork Adapter
1.
Remove the bearing shell from the angle head of the tool. For service tool, see Spare Parts of the
tool in question.
2.
Attach the fork adapter to the angle head.
3.
Clean the threads. Apply Loctite 2701, or similar, to the bearing shell adapter, and push it into the
fork adapter. Note: this is not the same bearing shell as the one for the angle head, in Step 1.
4.
Clean the threads. Apply Loctite 2701, or similar, to the threads of the adapter, and screw it onto the
fork adapter.
5.
Fasten the GFA module in a vice. Attach the adapter of the tool to the nut of the GFA module.
6.
Tighten the nut.
EN