Printed Matter No.9839 1814 01
Publication Date 2021-01-13
Valid from Serial No. -
Open-end and Offset
Geared Front Attachments
Read all safety warnings and instructions
Failure to follow the safety warnings and instructions may result in
electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference
WARNING
GFA-OOT
Geared Front Attachment
Product Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GFA-OOT and is the answer not in the manual?

Questions and answers

Summary of Contents for Saltus GFA-OOT

  • Page 1 GFA-OOT Printed Matter No.9839 1814 01 Geared Front Attachment Publication Date 2021-01-13 Valid from Serial No. - Product Instructions Open-end and Offset Geared Front Attachments WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in electric shock, fire and/or serious injury.
  • Page 2 Table of Contents Product Instructions ....................3 © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 3: Product Information

    The modular structure of the system allows for a wide range of configurations available for different screw connections and tightening processes. System Components The modular GFA system is made up of the following main components: © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 4 The open-end type can be used for pipe and hose connections. The closed-end type is used for regular screw con- nections. Output socket With different sockets the GFA system can be used for various screw profiles. GFA System Components © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 5: Installation Instructions

    (1) matches the input gear profile (square hole) of the GFA module (2). Functional Test Perform a functional test before the first tightening operation and after any performed maintenance activ- ity. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 6 GFA module. If it is hard to turn, open the housing and check that all components are in the correct position. Grease the system. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 7: Operation

    In dusty environments, use a dust extraction system or wear a mouth protection mask. Operating Instructions Operating the GFA System WARNING Crushing Hazard Never reach into the open-end head. Moving parts can crush and cut. Keep hands and fingers away from moving parts. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 8 Switch off the drive unit. Remove the system from the screw connection. The system can now be positioned on the next con- nection. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 9: Service Overview

    To clean the system, wipe carefully with a clean, smooth cloth. Lubrication Instructions Lubrication Instructions Recommended Component Lubricant Quantity GFA module Molykote Longterm 2 Plus Until excess grease emerges on the output socket © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 10 10. Remove the nut from the bearing housing. 11. Remove the input gear from the bearing housing. Remove the ball bearing from the input gear if needed. 12. Remove the needle roller bearing from the input gear. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 11 GFA-OOT Service © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 12 19. Screw the adapter onto the bearing housing until it stops. Secure the housing in a vice and tighten the nut. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 13 GFA-OOT Service © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 14 The adapter is fixed to the drive unit with Loctite. Loosening the tool from the adapter requires strong force. It is recommended to use a heat gun to facilitate the loosening. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 15 Fasten the GFA in a vice and attach the adapter to the nut. Tighten the nut. For service tool and tightening torque information, see the spare parts list of the spe- cific GFA model. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 16 If applicable, fasten the tool's bearing shell to the angle head. Note: this is not the same bearing shell as the one for the adapter, in Step 4. For service tool, see Spare Parts of the tool in question. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 17 Clean the threads. Apply Loctite 2701, or similar, to the threads of the adapter, and screw it onto the fork adapter. Fasten the GFA module in a vice. Attach the adapter of the tool to the nut of the GFA module. Tighten the nut. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 18 Service GFA-OOT © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 19: Environmental Regulations

    When a product has served its purpose it has to be recycled properly. Dismantle the product and recycle the components in accordance with local legislation. Batteries shall be taken care of by your national battery recovery organization. © Saltus Industrial Technique AB - 9839 1814 01...
  • Page 20 Original instructions © Copyright 2021, Saltus Industrial Technique AB. All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings. Use only authorized parts. Any damage or malfunction caused by the Saltus Industrial Technique AB use of unauthorized parts is not covered by Warranty or Product Liability.