GAS REQUIREMENTS

EN
Gas Tank Specifications
Any L.P. gas supply cylinder used with
this side burner must be approximate-
ly 12 inches diameter and 18 inches
high. The maximum fuel capacity is
80% and is approximately 20 pounds
of propane.
The L.P. cylinder must have a shut-off
valve (see picture) terminating in a
Type 1 L.P.
A Type 1 compatible cylinder with a
Type 1-cylinder valve has a back-
check valve which does not permit gas flow, until a positive seal
has been obtained.
The cylinder must be arranged for vapor withdrawal. It must also
include a collar to protect the cylinder valve. A safety relief device
having direct communication with the vapor space of cylinder must
be provided. This will expel high pressure gas if the cylinder is
overfilled or overheated which could result in fire or explosion.
All L.P. gas cylinders used with this appliance shall be construct-
ed and marked in accordance with the specifications for L.P. gas
cylinders of the US Department of Transportation (DOT) or the
National Standard of Canada, CAN/CSA-8339, Cylinders, Spheres
and Tubes for Transportation of Dangerous Goods; and Commis-
sion, as applicable; and shall be provided with a listed overfilling
prevention device.
Read labels on the L.P. Gas Supply Cylinder.
New cylinders are always shipped empty for safety.
Allow only qualified L.P. gas dealers to fill or repair your L.P. gas
supply cylinder.
Inform the gas dealer if it is a new or used cylinder to be filled.
After filling, have the gas dealer check for leaks and to see that the
relief valve remains effective and in good condition.
Shutoff
Valve
Collar