Option
SEG19
Explanation
PAGE
Indication Details Indication Details
Indication
and
3
Details
 If you input a number other than 0~4 on the individual control of the indoor unit(SEG 20), the indoor is
set as "Indoor 1".
Example) If you want to set as "Exterior temperature sensor : USE, External control : USE, Number of hours
using filer : 2000hr",
SEG1
0
SEG7
1
SEG13
2
SEG19
3
assign option codes except SEG 1, 7, 13, 19 which are page options.
4-6
SEG20
Individual control of
a remote controller
0 or 1 Indoor 1
2
Indoor 2
3
Indoor 3
4
Indoor 4
SEG2
SEG3
2
-
SEG8
SEG9
0
-
SEG14
SEG15
1
0
SEG20
SEG21
0
-
SEG21
SEG22
RESERVED
RESERVED
SEG4
1
SEG10
-
SEG16
-
SEG22
-
SEG23
Motion detect
sensor
Indication Details
0.No Use (Factory Setting)
1.Standard Mode/Auto
Set OFF30 Min.
2.Standard Mode/Auto
Set OFF60 Min.
3.Standard Mode/Auto
Set OFF 120 Min.
4.Standard Mode/Auto
Set OFF 180 Min.
5.Premium Mode/
Auto Set OFF30
Min.6.Premium Mode/
Auto Set OFF60 Min.
7.Premium Mode/Auto
Set OFF 120 Min.
8.Premium Mode/Auto
Set OFF 180 Min.
SEG5
SEG6
0
-
SEG11
SEG12
-
0
SEG17
SEG18
0
6
SEG23
SEG24
-
-
Samsung Electronics
SEG24
RESERVED