3.2
Quality point
When you assemble the unit, please check the following points for keeping the quality.
Do not apply excessive shock to the CMOS ASSY.
(It is 3-demensionally adjusted using adhesive.)
Between the CMOS and the MAIN, insert the FPC before assembly.
Do not fold the FPC at the edges of the reinforcing plate and the
connector.
(The broken terminal will result in disconnection.)
To replace the BARRIER UNIT, open the BARRIER to check the screws.
(The screws cannot be observed with the BARRIER closed.)
When attaching the TOP COVER, properly set the rear side.
To remove the TOP COVER, remove the screw on the HINGE in
addition to the 3 screws.
1-16 (No.YF412<Rev.001>)
All manuals and user guides at all-guides.com
OK
Between the CMOS and the MAIN, run the FPC under the mold.
(Running the FPC over the mold will result in poor contact because of
stress.)
Do not fold the FPC protruded from the HINGE COVER.
(Repeated opening/closing the monitor will break the FPC.)
When attaching the LOWER CASE, do not damage the parts or patterns on
the MAIN PWB.(Some models have shutter lever that cannot be separated.)
OK
When attaching the TOP COVER, properly set the rear side.
(Make sure there is no unevenness. Forcible attachment will result in
breakage.)
When tightening the screw [1] on the TOP side, make sure there is a space
[2].
(Without the space, the TOP COVER cannot be attached.)
Fig.3-2-1
NG
NG