INSTALLING & CLEANING FOAM WET FILTER
2
INSTALLING FOAM WET FILTER
1. Verify that the power cord is disconnected from the outlet (Fig.1).
2. Remove power head and place in upside down position. Follow instructions to remove the
cartridge filter on page 13.
3. Carefully slide the foam wet filter down over the filter cage making sure the cage is completely
covered (Fig. 2 & 3).
4. Place the power head back onto the collection tank.
CLEANING FOAM WET FILTER
1. With the removed power head in an upside down position, carefully remove the foam wet filter
(Fig. 4).
2. Use a mild soap and water solution to wash the foam wet filter and rinse with clean water (Fig. 5).
3. Allow the wet filter to air dry for 24 hours before installing onto the filter cage.
WARNING! TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE

TROUBLESHOOTING.

PROBLEM
The wet/dry vacuum will not
operate.
The dust comes out from the
motor cover.
Reduced efficiency and motor/
speed vibration.
3
TROUBLESHOOTING
POSSIBLE CAUSE
No power supply.
Faulty power cord.
Collection tank is full.
Switch in the wrong position.
The cartridge filter is missing or
damaged.
Vacuum has been used to
collect fine dust, such as dry
wall dust, fireplace soot, or ash,
without a fine dust filter.
There is a blockage in the
nozzle, hose, or the collection
tank inlets. The cartridge filter is
clogged by fine dust.
4
SOLUTION
Check the power supply, cord,
breakers, and fuses.
Unplug and check the power
cord. If damaged, have it
repaired by a professional.
Empty the collection tank.
Press the ON 'I' button on the
power head.
Attach or replace the cartridge
filter.
Remove the standard cartridge
filter and install the appropriate
fine dust filter.
Check nozzle, hose and
collection tank inlets for
blockage. Take off the filter and
clean it or install a new cartridge
filter.