Troubleshooting - Southbend EZ18-3 Operator's Manual

Electric, counter steamer
Table of Contents

Advertisement

INSTALLATION AND OPERATION MANUAL, PAN STEAMERS, MODELS EZ18-3, EZ18-5

8.0 TROUBLESHOOTING

GENERAL
PROBLEM
1. C
OOKING INDICATOR
LIGHT FAILS TO LIGHT
T
.
WITH
IMER SET
2. S
TEAM FAILS TO
GENERATE WITH
COOKING INDICATOR
.
LIGHT ON
3. S
TEAMS CONTINUOUSLY
WITHOUT THE COOKING
.
OR READY LIGHT ON
4. T
IMER DIAL NOT
.
TURNING
5.
BUZZER FAILS TO SOUND
AT END OF TIMER
.
SETTING
MANUAL 1195733 REV0 (11/22/2011)
PROBABLE CAUSE
a. Main power circuit breaker tripped.
b. Door interlock switch contacts not
closed.
c. Door interlock switch faulty.
d. Indicator light burned out.
e. Faulty timer contacts.
f. Faulty wiring.
g. Fuse blown.
a. Faulty wiring.
a. Faulty thermostatic switch.
b. Power switch - continuous steam
setting is selected.
a. Faulty timer motor.
b. Faulty wiring.
a. Timer contacts faulty.
b. Buzzer faulty.
c. Faulty wiring.
Locate external circuit breaker for incoming
power and place in ON position.
Shut cooker door to close switch contacts.
Check alignment of door with switch.
Replace switch.
Replace light.
Replace timer.
Inspect condition of wire and tightness of all
connections. Correct as needed.
Replace with same rated fuse.
Inspect condition of wire and tightness of all
connections. Correct as needed.
Replace thermostat.
This is normal operation when "continuous
steam" is selected.
Replace timer.
Inspect condition of wire and tightness of all
connections. Correct as needed.
Replace timer.
Replace buzzer.
Inspect condition of wire and tightness of all
connections. Correct as needed.
19
HEAVY DUTY STEAM
REMEDY

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ez18-5

Table of Contents