Advertisement

Quick Links

EAN-1500-OEM Startup Guide
2021-12-27
Exports:
Export Summary Sheet
EULA:
End User License Agreement
Web:
sightlineapplications.com
1
Overview ................................................................ 1
1.1
Additional Support Documentation ....................... 1
1.2
SightLine Software Requirements .......................... 1
2
Network Configuration .......................................... 1
3
Serial Communications .......................................... 2
4
1500-EVAL Kit ......................................................... 2
5
Hardware Bench Setup .......................................... 3
5.1
Power Connections ................................................ 4
6
Panel Plus ............................................................... 5
CAUTION: Alerts to a potential hazard that may result in personal injury, or an unsafe practice that causes damage to the equipment
if not avoided
IMPORTANT: Identifies crucial information that is important to setup and configuration procedures.
Used to emphasize points or reminds the user of something. Supplementary information that aids in the use or understanding of the
equipment or subject that is not critical to system use
© SightLine Applications, Inc.
Sales:
sales@sightlineapplications.com
Support:
support@sightlineapplications.com
6.1
6.2
Direct serial connection (optional): ....................... 7
7
Summary ................................................................ 8
7.1
Demo Mode ........................................................... 8
8
Troubleshooting ..................................................... 9
8.1
Questions and Additional Support ....................... 10
Appendix - 1500-OEM Enclosure .................................... 11
Phone: +1 (541) 716-5137

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EAN-1500-OEM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SightLine EAN-1500-OEM

  • Page 1: Table Of Contents

    Overview ..............1 Camera Setup and Network Selection ....7 Additional Support Documentation ....... 1 Direct serial connection (optional): ....... 7 SightLine Software Requirements ......1 Summary ..............8 Network Configuration .......... 1 Demo Mode ............8 Serial Communications .......... 2 Troubleshooting .............
  • Page 2: Overview

    EAN-Network Configuration for more network configuration information.  SightLine recommends assigning a static IP on the PC when a DHCP server is not present on the network.  If you require additional assistance with assigning a static IP address to the host PC, contact your network administrator or search online for procedures that corresponds with your current PC operating system.
  • Page 3: Serial Communications

    Parts listed below are included in the 1500-EVAL kit. If your application calls for other options and interface boards, please contact Sales. To review all the interface board options, see the 1500-OEM Accessories page on the SightLine Applications website. Table 1: 1500-EVAL Kit Part Number...
  • Page 4: Hardware Bench Setup

    PC. A green blinking light on the 1500-OEM board verifies network connection. SLA-PWR-B05V (110-250VAC input / 5VDC output): Connects to J2 on the SLA-1500-AB board. •  The camera and monitor are not provided by SightLine Applications. Analog SLA-CAB-2RCA Monitor...
  • Page 5: Power Connections

    1500-OEM power ON SLA-CAB-ETH0 SLA-PWR-B05V Figure 4: 1500-OEM Bench Setup with 1500-AB Board (Rev H and later) 1500-OEM power ON AB board power ON Switch Position SLA-PWR-A05V Figure 5: 1500-AB Board Dual Power Switches (Rev E and earlier) © SightLine Applications, Inc.
  • Page 6: Panel Plus

     IMPORTANT: The firmware version number and Panel Plus Software version number should match. If the board firmware version is initially unknown, reference the SightLine invoice that came with the board when it was purchased. 2. Launch the installer file and follow the prompts. After installation open the Panel Plus application.
  • Page 7 For more information about thermal management, see the ICD-1500-OEM. Firmware Ver: 3.3.1.6 FPGA:08, temp: 125°F [37°C] Operating 4:48:51 SVN Revision: 58309, Build Date: 01/11/2021, Build Time: information App bit code with listed features Figure 8: Operating Information © SightLine Applications, Inc.
  • Page 8: Camera Setup And Network Selection

     EAN-Camera Compatibility for all third-party cameras and lens assemblies that are currently supported by SightLine software. Includes configuration and setting support guidance. 5. From the Connect tab, click Stream Network Video to This PC. 6.2 Direct serial connection (optional): 1.
  • Page 9: Summary

    Tracker-only configuration. For configurations that include encoding, video will be displayed in the Panel Plus main window. Tracker-only configurations will display processed video on the analog output only. An analog monitor is required for viewing this output. © SightLine Applications, Inc.
  • Page 10: Troubleshooting

    The Panel Plus software will automatically recognize serial ports and list them in the dropdown menu for available connections. 6. Connecting to the serial COM port on the 1500-OEM board from a host PC requires a null modem adapter or null modem serial cable. © SightLine Applications, Inc.
  • Page 11: Questions And Additional Support

    Check network settings 8.1 Questions and Additional Support For questions and additional support, please contact Support. Additional support documentation and Engineering Application Notes (EANs) can be found on the Documentation page of the SightLine Applications website. © SightLine Applications, Inc.
  • Page 12: Appendix - 1500-Oem Enclosure

    BNC (F) to RCA (F) Adapter FFC Ribbon Cable to Supported Cameras (optional) Analog Monitor SLA-CAB-FF06 Camera SLA-CAB-SMA2BNC SLA-CAB-SMA2BNC 1500-OEM Enclosure SLA-PWR-B05V SLA-CAB-ETH0 Ethernet SLA-CAB-S001 Direct Serial Connection Network Switch or PC Direct Figure A1: 1500-OEM Enclosure Bench Connection Diagram © SightLine Applications, Inc.

Table of Contents