Canon i960 Service Manual page 19

Hide thumbs Also See for i960:
Table of Contents

Advertisement

5)
After the function (menu) is selected, press the Power button. The LED lights in green, and the
selected function is performed. (When the operation completes, the printer returns to the menu
selection mode automatically.)
<Destination settings procedures>
In the destination settings mode, press the Resume/Cancel button the specified number of time(s) according
to the destination listed in the table below, and press the Power button.
Time(s)
LED
1 time
Orange
Destination setting remains unchanged.
2 times
Green
Overseas, non-support of CD-R printing (A4):
3 times
Orange
Overseas, non-support of CD-R printing (LTR): i960 (LTR)
4 times
Green
Overseas, support of CD-R printing (A4):
5 times
Orange
Overseas, support of CD-R printing (LTR):
6 times
Return to the menu selection
or more
Note:
After setting the destination, confirm the model name in service test print or EEPROM information
print. (See 3.4. Verification Items, (1) Service test print, or (2) EEPROM information print.)
<Media sensor correction procedures>
In the media sensor correction mode, using the reference white PET paper and reference plain paper of the
calibration media kit (QY9-0064), press the Resume/Cancel button the specified number of times in the
table below, and press the Power button. The media sensor correction operation must be performed once
each with the reference white PET paper and the reference plain paper.
Time(s) of
Resume/Cancel button
1 time
2 times
3 times
4 times or more
Note:
- After each correction value operation, the mode returns to the service mode menu selection. After
finishing either of the correction value operations, re-select the media sensor correction mode to
perform the other correction value operation.
- After performing the media sensor correction, confirm the values of the media sensor in service
test print or EEPROM information print. (See 3.4. Verification Items, (1) Service test print, or (2)
EEPROM information print.)
*1: Reference white PET paper correction value operation
Set the A5-sized reference white PET paper (packed in the calibration media kit) in the sheet feeder in
the landscape orientation. Then, press the Resume/Cancel button 2 times, and the Power button.
Note:
There is no printing on the reference white PET paper. It can be placed with either side facing
up, and with either edge at top.
*2: Reference plain paper correction value operation
After setting a sheet of the A5-sized reference plain paper (packed in the calibration media kit) in the
sheet feeder, press the Resume/Cancel button 3 times, and the Power button.
The reference plain paper should be placed in the sheet
feeder with the print side facing up, with the + marks
printed area at top, so that it will feed in the direction
indicated by the blue arrow in the figure.
(7) Flash ROM upgrade
Refer to the PIXUS 860i / /i860 / i865 Service Manual.
Destination
LED
Orange
Not used in servicing
(In this mode, the set reference paper will be fed, and may be
damaged. Please be careful not to select this mode.)
Green
Reference white PET paper correction value operation
Orange
Reference plain paper correction value operation
Return to the menu selection
1 - 14
i960
i965
i965 (LTR)
Operation
*2
*1

Advertisement

Table of Contents