Download Print this page

Specifications - HomeSeer HS-WX300 User Manual

Advertisement

Parameter
Description
3
Sets bottom LED operation (in
normal mode)
4
Sets paddle's load orientation
5
Sets the lowest dimming threshold
6
Enables/Disables Central Scene
and multiple tap functions
11
Set dimmer Ramp rate for remote
control
12
Set dimmer Ramp rate for local
control
13
Sets the display mode of the LEDs
14
Sets the Normal display mode LED
color
21
Sets the Status mode LED 1
(bottom) color
22
Sets the Status mode LED 2 color
23
Sets the Status mode LED 3 color
24
Sets the Status mode LED 4 color
25
Sets the Status mode LED 5 color
26
Sets the Status mode LED 6 color
27
Sets the Status mode LED 7 (top)
color
30
Sets the dimmer Blink frequency
for All LEDs in Status mode
31
Sets LED(s) 1-7 to Blink in Status
mode
32
Sets the Wire mode / no neutral
mod of the switch

Specifications

Power
Requirements
Max Load
Incandescent | Dimmable
CFL/LED
Incandescent
Double-gang Box
De-rating
Triple-gang Box
Z-Wave
Frequency
Range
Dimensions
Metal Yoke
Plastic Housing
Bytes
Value
1
0 = all LED ON if load is OFF
1 = all LED OFF if load is OFF
1
0 = Top of Paddle turns load ON
1 = Bottom of Paddle turns load ON
1
Possible values: 1-14
3-wire mode (1=16%, 14=25%)
2-wire mode (1=25%, 14=30%)
1
0 = Central Scene Enabled, controls load with
delay. Enables Multi-tap and press and hold
1 = Central Scene Disabled, controls load
instantly. Disables multi-tap, central scene,
press and hold
1
Possible values: 0-90
0=No delay (instant ON), 1=1 second
1
Possible values: 0-90
0=No delay (instant ON), 1=1 second
1
0=Normal mode (LEDs show load status)
1=Status mode (custom LED status)
1
Possible values: 0-6
0=White, 1=Red, 2=Green, 3=Blue,
4=Magenta, 5=Yellow, 6=Cyan
1
1
1
Possible values: 0-7
0=Off, 1=Red, 2=Green, 3=Blue, 4=Magenta,
1
5=Yellow, 6=Cyan, 7=White
1
1
1
1
Possible values: 0, 1-255
0=No blink, 1=100ms ON then 100ms OFF
1
Bitmask defines specific LEDs to enable for
blinking:
Note: this decimal value is derived from a hex
code calculation
based on the following:
Bit 0 = led 1, Bit 1 = led 2, Bit 2 = led 3, Bit 3 =
led 4, Bit 4 = led 5,
Bit 5 = led 6, Bit 6 = led 7
IE: value of 1 = first LED, 64 = led 7
1
0 = 3 wire mode (Neutral, Line, & Load)
1 = 2 wire mode (Line & Load)
120VAC / 60 Hz
600 watts | 300 watts
500 watts
400 watts
908.4/916 MHz (US/CAN)
100+ ft. (line of sight)
1.79" x 4.13" (45.5mm x
105mm) (W x H)
1.72" x 2.68" x 1.18" (43.7mm
x 68mm x 30mm) (W x H x D)
Default
Dimmer
Switch
Mode
Mode
1
Y
Y
0
Y
Y
1
Y
N
0
Y
Y
3
Y
N
3
Y
N
0
Y
Y
0
Y
Y
0
Y
Y
5
Y
Y
0
Y
Y
0
Y
Y

Advertisement

loading