3. Disassembly and Reassembly
Part
SYCHRONOUS
MOROR
&
DISTRIBUTOR
HEATER HOUSING
ASS'Y (1)
All manuals and user guides at all-guides.com
Photo
1) Remove the two (2)SYCHRONOUS MOTOR
2) Remove the two (2) screws holding SYCHRONOUS
3) Remove the SYCHRONOUS MOTOR and
1) Remove the all HEATER HOUSING ASS'Y connectors.
2) Remove the five (5) screws holding HEATER
3) Remove the HEATER HOUSING ASS'Y and HEATER
Description
26.Sychronous motor & Distributor
Separate top table ass'y
Separate housing L/R
Separate main pcb ass'y
Separate tub ass'y
Separate sump ass'y
connectors.
MOTOR in place.
DISTRIBUTOR.
27.Heater housing ass'y (1)
Separate top table ass'y
Separate housing L/R
Separate main pcb ass'y
Separate tub ass'y
Separate sump ass'y
HOUSING ASS'Y in place.
HOUSING SEAL.
Caution
* If necessary, rub with a dry towel remainning water
water in order to keep clean SUMP ASS'Y.
* In assembling, confirm the assembly condition of
contact heater housing gasket.
* When heater housing gasket is deformation, you
must change new one.