Summary of Contents for Netio PowerCable Modbus 101 Series

  • Page 1 PowerCable xxx 101x MANUAL - PowerCable Modbus 101x - PowerCable MQTT 101x - PowerCable REST 101x 29. 4. 2020...
  • Page 2: Table Of Contents

    5. 2. 1 NETIO Mobil e2 f or Android ....... .
  • Page 4: Introduction

    Introduction Thank you f or purchasing t his product of NETIO product s a. s. Bef ore using your product , please read t his (MAN) and t he included t o avoid problems wit h User Manual Quick Installation Guide (QIG) incorrect inst al lat ion or use.
  • Page 5  ZCS (Zero Current Swit ching) IOC (Independent Out put Cont rol )   PowerUp st at e - (ON / OFF / LAST)  1. 2m cabl e Overvolt age prot ect ion  Operat i ng t emperat ure range: -20° C t o +65° C ...
  • Page 6 Modbus 101x REST 101x MQTT 101x Web int erf ace Telnet Modbus/ TCP URL API XML API JSON API MQTT-flex Netio Push JSON Netio Push XML SNMP v1 PowerCable PowerCable PowerCable Modbus 101x REST 101x MQTT 101x NETIO Cloud NETIO Mobile2...
  • Page 7 Overview of models according t o t he el ect rical socket t ype Max. Max. Variant Output socket Input plug Voltage Model current load 101F Type F E/ F (CEE 7/ 7) 230V ~ 3600W 101E Type E E/ F (CEE 7/ 7) 230V ~ 3600W 101J...
  • Page 8: Powercable Xxx

    4 Specifications 101E, 101F: 230V~; 50Hz; 16A 101J: 230V~; 50Hz; 10A Power 101S: 110/230V~; 60/50Hz; 10A 101G: 230V~; 50Hz; 13A 101B: 110V~; 60Hz; 15A 101E, 101F: 230V~; 50Hz; 16[8]A; max. 3600W 101J: 230V~; 50Hz; 10[8]A; max. 2300W Swit ched out put s 101S: 110/230V~;...
  • Page 9: Specifications Of Different Socket Types

    4. 1 Specifications of different socket types NETIO products a. s. supplies the PowerCable xxx 101x in several variants with different elect rical plug/ out let t ypes. Figur e 1 - Power Cabl e xxx 101F (DE–schuko - Type F) Figur e 2 - Power Cabl e xxx 101E (FR –Type E)
  • Page 10 Figur e 4 - Power Cabl e xxx 101S (IEC-320 C13/ C14) Figur e 5 - Power Cabl e xxx 101B (US –Type B) Figur e 6 - Power Cabl e xxx 101G (UK –Type G)
  • Page 11: Features

    The negat ive ef f ect s of inrush current on t he lif et ime of t he relay i n t he  NETIO device are signif icant ly reduced. Reduced probabi lit y of a circuit breaker t rippi ng in t he circuit branch ...
  • Page 12 <1% Quick WiFi connection setup (AP mode installation)  NETIO PowerCabl e creat es a WiFi net work t hat you connect t o wit h your PC or mobile phone.  It t hen scans f or WiFi net works in t he vicinit y, and let s you choose f rom a list and t ype t he password.
  • Page 13: Drawings

    4. 3 Drawings Figur e 7 – PoweCabl e xxx 101x side view Figur e 8 – PoweCabl e xxx 101x t op view...
  • Page 14: Device Description

    4. 4 Device description Front view 1. Status LED (yellow) 2. Output LED (green) 3. Button – to press, a thin object is needed (may be conductive) 4. Type plate – indicates the device model, electrical rating, maximum switching power and serial number (fig. 11) Figur e 9 –...
  • Page 15: Led And Button Functions

    4. 5 LED and button functions Button functions Controlling Press 3x within 1 to 5 seconds to switch the output. the output Press and hold for 10 seconds in the standard operating mode. AP mode Hold until the yellow LED (1) starts flashing rapidly. activation The AP mode is activated, making it possible to connect to the device and change the WiFi network to which it should connect.
  • Page 16: Package Contents

    4. 7 Package contents PowerCable NETIO product Quick Inst allat ion Gui de (QIG) Figur e 11a – PoweCabl e xxx 101x package...
  • Page 17: Configuration And Control

     Pl ug t he NETIO PowerCabl e int o t he elect rical net work. When t he device is powered up f or t he f irst t ime, it ent ers t he “ AP mode” t hat enabl es basic conf igurat ion – select ion of a WiFi net work t o which t he device wil l connect (yel low LED f lashes rapi dly).
  • Page 18  Sel ect your net work in t he list of det ect ed net works and click “ Next ” (Figure 14). Ent er t he password f or t he select ed WiFi net work. You may also change t he devi ce name. If ...
  • Page 19  A page wit h t he connect ion result is displayed. If it shows “ WiFi st at us: Connect ed“ , check t he net work paramet ers and t hen click “ Save&Connect ” t o save t he conf igurat ion (Figure 17). The device t hen exit s t he AP mode, connect s t o t he select ed WiFi net work, and displays a net work conf igurat ion summary page (Figure 18).
  • Page 20: Nfc Installation In 60 Seconds

    NFC (Near Field Communi cat ion) is a t echnology support ed by some mobi le phones (and t ablet s). Using a mobile phone wit h NFC support and t he NETIO Mobile 2 app, even a device t hat is powered of f can be conf igured.
  • Page 21 Ent er t he IP address int o a web browser or t he NETIO Mobile app and log in t o t he device. For MAC or Linux users use t he NETIO Discover Mult i pl at f orm version.
  • Page 22: Login To Device Web

    5. 4 Login to device web Figur e 21 – Power Cabl e l ogin dial og To log in, use admin admin (def ault login username / password)
  • Page 23: Restoring Factory Defaults

    5. 5 Restoring factory defaults This operat ion delet es al l user set t i ngs and rest ores t he conf igurat ion t o t he f act ory def ault s. It is usef ul when t he device is in an unknown st at e or does not behave as described i n t his manual . Procedure: Turn of f t he PowerCable.
  • Page 24: Controlling The Output Manually

    5. 6 Controlling the output manually The out put can be swit ched on/ of f (t oggled) by pressing t he but t on quickl y 3 t imes in a row. Figur e 23 – LED indi cat ion f or manual out put cont r ol...
  • Page 25: Web Interface

    6 Web interface 6. 1 Outputs In t he lef t menu, click Outputs . A screen showing t he PowerCabl e out put appears. The out put can be cont rol led direct l y wit h t wo but t ons: Figur e 24 –...
  • Page 26: Out Put S - Energy Measurement S

    Reset but t on swit ches t he out put of f and t hen back on. A conf irmat ion is request ed bef ore t he act ion is perf ormed. The f unct ion is enabled only when t he out put is swit ched on. When t he out put is swit ched of f , t he Reset but t on is disabl ed.
  • Page 27: Out Put S - General

    Energy i n wat t -hours ( Wh / kWh ) is t he cumulat ive energy consumed over a t ime int erval . The value is t he t ot al consumpt ion at t he out put since t he last reset of t he count er. By def ault , t he cumulat ive energy consumpt ion is count ed f rom t he t ime t he PowerCabl e was f irst powered on.
  • Page 28 Figur e 27 – Reset t ing t he consumpt ion count er...
  • Page 29: M2M Api Protocol Actions

    6. 2 M2M API Protocol Actions All M2M prot ocols use t he same values f or t he paramet er t o cont rol t he out put . Al lowed act ion values are: 0 – t urns t he out put of f 1 –...
  • Page 30: Cloud

    6. 3 Cloud Net io Cloud is a service provided by NETIO Product s a. s. and al low easy cent ral remot e cont rol and monit oring of t he NETIO devices. What can you do in NETIO Cloud? Out put cont rol ...
  • Page 31 Connect ion t o NETIO Cloud can be conf igured on Cloud t ab. Figur e 27b – Cl oud conf igur at ion Check t o enable NETIO Cloud. Enable NET IO Cloud Disconnected : Device not connect ed t o Cloud St at us Cloud connect faild…...
  • Page 32 Saves t he changes. Save Changes Ent er t he regist rat ion t oken f rom NETIO Cloud web - shown when “ ADD Regist rat ion t oken DEVICE” but t on used. Then press “ Add device” but t on.
  • Page 33: Users

    6. 4 Users When several users use t he PowerCable, it is advisable t o assign t hem dif f erent account s wit h t he necessary privil eges. In t he lef t menu, sel ect Users . Figur e 28 –...
  • Page 34 Only an admi nist rat or or a user wit h t he “ manage users” privilege may change t he passwords of ot her users. Note : U ser based account can be used f or access t o NETIO Mobile2 App.
  • Page 35: Settings

    6. 5 Settings To ensure correct operat ion as int ended, t he device set t ings need t o be properly conf igured. Sel ect Settings in t he lef t menu t o display a sub-menu wit h product set t i ngs. 6.
  • Page 36: Net Work Configurat Ion

    6. 5. 2 Net work Configurat ion This sect ion allows conf iguring t he IP paramet ers of t he PowerCable net work int erf ace which are essent ial f or correct net work operat ion. Figur e 30 – Net wor k conf igur at ion Et hernet address of t he net work adapt er.
  • Page 37 unsure, ent er a public DNS server, such as: 8. 8. 8. 8 Name of t he device in t he local net work. It is generat ed f rom t he Device Host name name (unsupport ed charact ers are replaced). Saves t he changes.
  • Page 38: Dat E / Time

    6. 5. 3 Dat e / T ime In t he Set t ings menu on t he l ef t , select Date/ Time . Figur e 31 – Dat e / t ime set t ings When select ed, t he device’ s clock is periodically synchronized wit h a Use NT P server NTP server.
  • Page 39: Firmware

    6. 5. 4 Firmware Firmware sect ion allows updat ing t he f irmware of your device. The current f irmware version is shown in t he f oot er of each page. Figur e 32 – Det ail s about t he inst al l ed f ir mwar e Inst alled f irmware version.
  • Page 40 Figur e 32b – WEB of NETIO pr oduct s – Li nk t o Fir mwar e downl oad Figur e 33 – Fir mwar e downl oad l ink at t he net io-pr oduct s. com websit e...
  • Page 41: Syst Em

    Current ly inst alled f irmware version and a link t o t he f irmware Firmware version download page. Shown in NETIO Discover and under t he device logo in t he web Device name administ rat ion (in t he f igure above: Power Cabl e-70 under t he...
  • Page 42 Adds a DebugLog sect ion wit h diagnost ic values t o XML and JSON M2M Debug Log API. Delay in seconds bet ween powering up t he device and swit ching on t he Global Out put s PowerUp out put .
  • Page 43: Log

    6. 6 Log In t he lef t menu, sel ect Log . Figur e 35 - Event l og Reloads t he log t o show t he most recent ent ries. Refresh Export s t he log in t he ht ml f ormat . Export t o file Clears t he log records.
  • Page 44: Powercable Rest 101X

    7 PowerCable REST 101x 7. 1 Overview Only one protocol can be active!
  • Page 45: M2M Api Protocol - Xml (Rest M2M Api)

    Username f or t he respect ive access mode (Read-Only/ ReadWrit e). Note Username – t his is unrelat ed t o t he username f or accessing t he NETIO 4x web administ rat ion int erf ace. When lef t empt y, t he prot ocol will not require any aut hent icat ion.
  • Page 46 Af t er ent ering t he username and password, you wil l receive an xml f i le wit h t he PowerCable current st at e. URL f or downloading/ uploading t he net io. xml f ile: htt p:/ / <PowerCableIP>/ netio. xml e. g. ht t p: / / 192. 168. 120. 75/ net io. xml Exampl e of t he net io.
  • Page 47 <Delay>2000</Delay> <PowerFactor>1.00</PowerFactor> <Load>0</Load> <Current>0</Current> <Energy>0</Energy> </Output> </Outputs> </set:Root> The f ollowing exampl e XML f iles f or cont rolli ng t he device can be downloaded di rect ly f rom t he web administ rat ion: • Set out put 1 t o ON •...
  • Page 48 For more inf ormat ion and a pract ical demonst rat ion of using t he XML prot ocol wit h PowerCabl e smart socket s, see t he f ol l owing Applicat ion Not e: AN20 XML HTTP(s) prot ocol t o cont rol NETIO smart power socket s 110/ 230V...
  • Page 49: M2M Api Protocol - Json (Rest M2M Api)

    7. 3 M2M API Protocol – JSON (REST M2M API) Available only in PowerCable REST 101x Figur e 38 – JSON API pr ot ocol conf igur at ion Enables M2M JSON API f unct ions in t he syst em kernel. Enable JSON API Read-only value.
  • Page 50 Af t er ent ering t he username and password, you wil l receive a j son f ile wit h t he PowerCable current st at e. URL f or downloading/ uploading t he net io. j son f ile: ht tp:/ / <PowerCableIP>/ netio. j son e. g. ht t p: / / 192. 168. 120. 75/ net io. j son Exampl e of t he net io.
  • Page 51 For more inf ormat ion about t he M2M JSON API, visit t he Support > Download sect ion of our websit e and see t he f ollowing document : JSON - descript ion of NETIO M2M API i nt erf ace - PDF...
  • Page 52 For more inf ormat ion and a pract ical demonst rat ion of using t he JSON prot ocol wit h PowerCabl e smart socket s, see t he f ol l owing Applicat ion Not e: AN21 JSON HTTP(S) prot ocol t o cont rol NETIO 110/ 230V power socket s (3x REST API)
  • Page 53: M2M Api Protocol - Url-Api (Rest M2M Api)

    7. 4 M2M API Protocol – URL-API (REST M2M API) Available only in PowerCable REST 101x Figur e 40 –URL API pr ot ocol conf igur at ion Enables M2M URL API f unct ions in t he syst em kernel. Enable URL API Read-only value.
  • Page 54 For more inf ormat ion about t he M2M URL API, visit t he Support > Download sect ion of our websit e and see t he f ollowing document : URL API - descript ion of NETIO M2M API int erf ace - PDF...
  • Page 55 For more inf ormat ion and a pract ical demonst rat ion of using t he URL-API prot ocol wit h PowerCable smart socket s, see t he f ol l owing Applicat ion Not e: AN19 URL API (ht t p GET) prot ocol t o cont rol NETIO 4x power socket s/ out let s 110 / 230V...
  • Page 56: M2M Api Protocol - Snmp

    7. 5 M2M API Protocol – SNMP SNMP is available from FW version 2. 6. 0 in t hese devices as one of M2M protocols: PowerCable REST 101x   PowerCable Modbus 101x PowerCable MQTT 101x.  Figur e 40a – SNMP API pr ot ocol conf igur at ion Enables M2M SNMP API f unct ions in t he syst em kernel.
  • Page 57 Saves t he changes. Save Changes Use t his but t on t u download MIB. Download MIB file When t he SNMP API is enabled, ot her M2M prot ocols are disabled. Af t er clicking Save changes , you will be asked t o conf irm t he deact ivat ion of t he ot her prot ocols.
  • Page 58 For more inf ormat ion about t he M2M SNMP API, visit t he Support > Download sect ion of our websit e and see t he f ollowing document : SNMP API - descript ion of NETIO M2M API i nt erf ace - PDF Note: There are differences compare to description in PDF: ...
  • Page 59: Powercable Modbus 101X

    8 PowerCable Modbus 101x 8. 1 Overview Only one protocol can be active!
  • Page 60: M2M Api Protocol - Modbus/ Tcp

    8. 2 M2M API Protocol – Modbus/ TCP Available only in PowerCable MODBUS 101x Figur e 41 –Modbus/ TCP pr ot ocol conf igur at ion Enables M2M Modbus/ TCP f unct ions in t he syst em kernel. Enable Modbus/ T CP Specif ic port f or Modbus/ TCP only, range 1 –...
  • Page 61 0x01 2nd output state 0x01 3rd output state 0x01 4th output state 0x03 uInt16 Number of digital inputs 0x03 uInt16 Number of digital outputs 0x03 uInt16 Number of measured digital outputs 0x03 uInt16 1st output state 0x03 uInt16 2nd output state 0x03 uInt16 3rd output state...
  • Page 62 For more inf ormat ion about t he M2M Modbus/ TCP prot ocol, visit t he Support > Download sect i on of our websit e and see t he f ol lowing document : Modbus / TCP - descript ion of NETIO M2M API i nt erf ace - PDF...
  • Page 63 For more inf ormat ion and a pract ical demonst rat ion of using t he Modbus/ TCP prot ocol wit h PowerCable smart socket s, see t he f ol lowing Applicat ion Not e: AN27: Modbus/ TCP wit h NETIO 4x – Cont rol and measure LAN power socket s...
  • Page 64: M2M Api Protocol - Telnet

    8. 3 M2M API Protocol – Telnet Available only in PowerCable MODBUS 101x Figur e 42 –Tel net pr ot ocol conf igur at ion Enables M2M Telnet f unct ions in t he syst em kernel. Enable T elnet Specif ic port f or Telnet only, range 1 –...
  • Page 65 (Figure 42) <password> Example – log in with username net i o and password passwd : login netio passwd quit Log out and t erminat e Telnet connect ion. noop Keep t he Telnet connect ion alive f or t he next 60 seconds.
  • Page 66 Parameters <action> for port command Parameter Action Turn OFF Turn OFF Short OFF delay (rest art ) Short ON delay Toggle (invert t he st at e) No change Command examples Switch power out put 1 to ON: port 1 1 Switch power out put 1 to OFF: port 1 0 Toggle power out put 1:...
  • Page 67 For more inf ormat ion about t he Telnet prot ocol, visit t he Support > Download sect ion of our websit e and see t he f ollowing document : Tel net - descript ion of NETIO M2M API i nt erf ace - PDF...
  • Page 68: M2M Api Protocol - Snmp

    For more inf ormat ion and a pract ical demonst rat ion of using t he Modbus/ TCP prot ocol wit h PowerCable smart socket s, see t he f ol lowing Applicat ion Not e: AN10 Tel net cont rol of el ect rical power socket s (M2M API – KSHELL) 8.
  • Page 69: Powercable Mqtt 101X

    9 PowerCable MQTT 101x 9. 1 Overview Only one protocol can be active!
  • Page 70: M2M Api Protocol - Mqtt-Flex

    9. 2 M2M API Protocol – MQTT-flex Available only in PowerCable MQTT 101x Figur e 43 – MQTT-f l ex pr ot ocol conf igur at ion Enables MQTT-f lex f unct ions in t he syst em kernel. Enable MQT T - flex Text area for entering the MQTT- f lex configuration.
  • Page 71 MQTT-f l ex conf igurat ion example: "config":{ "broker":{ "type":"generic", "protocol":"mqtt", "ssl":"false", "url":"broker.hivemq.com", "port":1883, "username":"", "password":"" "subscribe":[ "topic":"netio/${DEVICE_NAME}/output/1/action", "qos":0, "target":"OUTPUTS/1/ACTION", "action":"${payload}" "topic":"netio/${DEVICE_NAME}/output/1/delay", "qos":0, "target":"OUTPUTS/1/DELAY", "action":"${payload}" "publish":[ "topic":"netio/${DEVICE_NAME}/output/1/voltage", "qos":0, "retain":false, "payload":"${OUTPUTS/1/VOLTAGE} V", "events":[ "type":"delta", "source":"OUTPUTS/1/VOLTAGE", "delta":40 "type":"timer", "period":3600 "topic":"netio/${DEVICE_NAME}/output/1/state", "qos":0, "retain":true, "payload":"${OUTPUTS/1/STATE}",...
  • Page 72 Download sect ion of our websit e and see t he f ollowing document : MQTT-f l ex - descri pt ion of NETIO M2M API int erf ace - PDF There are wide opt ions f or subscribe and publish sect i ons and it s possibilit ies expand over t he t ime.
  • Page 73: M2M Api Protocol - Netio Push

    9. 3 M2M API Protocol – Netio Push Available only in PowerCable MQTT 101x Figur e 44 –Net io Push pr ot ocol conf igur at ion Enables Net io Push f unct ions in t he syst em kernel.
  • Page 74: M2M Api Protocol - Snmp

    For more inf ormat ion about t he M2M HTTP(s) Push API, visit t he Support > Download sect ion of our websit e and see t he f ollowing document : HTTP(s) Push XML/ JSON - descript ion of NETIO M2M API int erf ace - PDF 9. 4 M2M API Protocol – SNMP...
  • Page 75: Powercable Oem Devkit 101X

    10 PowerCable OEM DevKit 101x 10. 1 Overview PowerCable OEM DevKit is ideal for use by developers to test functionalities of selected M2M prot ocols wit h own system. It supports all available M2M prot okols according to previous chapters. Only one protocol can be active!
  • Page 76: Oem - Custom Modifications (Customizations)

    . Def i ned product name wi ll be list ed on t he websit e, bot t om black label wit hout NETIO as manuf act ure and on t he paper box. All CE cert if icat ion it ems st ay as predef ined.
  • Page 77: Declaration Of Conformity (Red Ce)

    This declaration of conformity is issued under the sole responsibility of the manufacturer. Obj ect of t he declarat ion: “ Ext ension socket NETIO PowerCable 101x cont rolled and monit ored over t he WiFi / LAN net work” .
  • Page 78: Netio Products Overview

    12 NETIO products overview WiFi / IQRF Output Switched Metered Button(s) Industrial Power-Up Power (RJ45) Antenna 868MHz Type outputs outputs Inputs / LED features state ZCS, 110/ 230V / 10A 4 / 4 PowerPDU 4C RS232 110/ 230V / 10A...
  • Page 79 NETIO products – features Scheduler IP Wat adog function function scripting √ √ √ √ √ √ √ v1/ v3 √ PowerPDU 4C √ √ √ √ √ √ √ planed PowerPDU 4PS √ √ √ √ √ √ √...

This manual is also suitable for: