Grohe Blue UltraSafe Pure 31 328 Manual page 4

Starter kit

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
GB
GB
Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.
The water filtrate is classified as Category 2 according
to EN 1717.
Safety notes
Avoid danger due to damaged power cords. In the
case of damage, the control unit must be replaced by
the manufacturer or his customer service department
or an equally qualified person.
• For hygiene reasons, the filter system must be flushed
before using for the first time.
• The filter system must always be operated with cold water
of foodstuff grade.
• The filter head is equipped with a non-return valve according
to EN 13959.
• The filter head must be replaced after 5 years.
• The control unit and plug must not be directly or indirectly
sprayed with water when cleaning.
• The control unit must be connected to a permanent power
supply.
• At the installation location, the filter system must be
protected against mechanical damage, heat and direct
sunlight.
Do not install near heat sources or an open fire.
• Installation of the fitting with filter cartridge is only permitted
in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
Electrical data:
• Voltage supply:
• Power consumption:
• Standby power loss:
• Type of protection
– Control unit:
– Mains plug:
Sanitary data:
• Flow pressure:
– min.
– recommended
• Operating pressure
– Fitting:
– Filter cartridge and filter head:
• Test pressure of fitting:
1
Avoid major pressure differences between hot and cold water
supply.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Note
The installation of a pressure reducing valve can affect flow
reducing.
For proper operation of the filter system, the pressure must not
be less than 0.08 MPa.
• Flow rate at 0.3 MPa flow pressure
• Ambient temperature:
• Temperature
• Water connection:
• Filter capacity:
Note
The filter capacity is specified for defined test conditions,
the actual capacity in operation may be higher or lower.
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Approval and conformity
The conformity declarations can be obtained from the following
address:
100 – 240 V AC / 50/60 Hz
GROHE Deutschland Vertriebs GmbH
9 W
Zur Porta 9
< 1.0 W
D-32457 Porta Westfalica
IP 68
IP 40
Electrical installation
0.1 MPa
0.2 – 0.5 MPa
max. 0.8 MPa
0.12 – 0.8 MPa
1.6 MPa
– Fitting (tap water):
– Filter cartridge (GROHE Blue
– Hot water inlet:
– Recommended (energy saving):
– Water inlet temperature filter:
This product conforms to the requirements of the
relevant EU guidelines.
Electrical installation work must only be performed by
a qualified electrician. This work must be carried out
in accordance with the regulations according to
IEC 364-7-701-1984 (corresponding to VDE 0100
Part 701) as well as all national and local regulations.
approx. 9 l/min
®
water): approx. 2.75 l/min
4 – 30 °C
max. 70 °C
60 °C
max. 30 °C
cold – blue
hot – red
max. 600 litres corresponds
to max. 6 months
A
2
2,500 V
100 °C