Service And Maintenance Procedures - Carrier F96CTN Installation, Start-Up, Operating, Service And Maintenance Instructions

Two-stage, variable-speed, multipoise 35 in. (889 mm) tall, condensing gas furnace
Table of Contents

Advertisement

F96CTN and G96CTN (Series A): Installation, Start-up, Operating, Service and Maintenance Instructions
Fig. 66 – Service Label Information
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Table 21 – Gas Rate (CU ft./hr)
SIZE OF TEST DIAL
SECONDS
FOR 1 REV
1 Cu
Ft.
10
360
11
327
12
300
13
277
14
257
15
240
16
225
17
212
18
200
19
189
20
180
21
171
22
164
23
157
24
150
25
144
26
138
27
133
28
129
29
124
30
120
31
116
32
113
33
109
34
106
35
103
36
100
37
97
38
95
39
92
40
90
41
88
42
86
43
84
44
82
45
80
46
78
47
76
48
75
49
73

SERVICE AND MAINTENANCE PROCEDURES

Untrained personnel can perform basic maintenance functions such as
cleaning and replacing air filters. All other operations must be performed
by trained service personnel. A qualified service person should inspect
the furnace once a year.
FIRE, INJURY OR DEATH HAZARD
Failure to follow this warning could result in personal injury, death
A190158
and/or property damage.
The ability to properly perform maintenance on this equipment requires
certain knowledge, mechanical skills, tools, and equipment. If you do
not possess these, do not attempt to perform any service and
maintenance on this equipment other than those procedures
recommended in the Owner's Manual.
60
SECONDS
FOR 1 REV
2 Cu
5 Cu
1 Cu
Ft.
Ft.
Ft.
720
1800
50
72
655
1636
51
71
600
1500
52
69
555
1385
53
68
514
1286
54
67
480
1200
55
65
450
1125
56
64
424
1059
57
63
400
1000
58
62
379
947
59
61
360
900
60
60
343
857
62
58
327
818
64
56
313
783
66
54
300
750
68
53
288
720
70
51
277
692
72
50
267
667
74
48
257
643
76
47
248
621
78
46
240
600
80
45
232
581
82
44
225
563
84
43
218
545
86
42
212
529
88
41
206
514
90
40
200
500
92
39
195
486
94
38
189
474
96
38
185
462
98
37
180
450
100
36
176
439
102
35
172
429
104
35
167
419
106
34
164
409
108
33
160
400
110
33
157
391
112
32
153
383
116
31
150
375
120
30
147
367
WARNING
!
SIZE OF TEST
DIAL
2 Cu
5 Cu
Ft.
Ft.
144
360
141
355
138
346
136
340
133
333
131
327
129
321
126
316
124
310
122
305
120
300
116
290
112
281
109
273
106
265
103
257
100
250
97
243
95
237
92
231
90
225
88
220
86
214
84
209
82
205
80
200
78
196
76
192
75
188
74
184
72
180
71
178
69
173
68
170
67
167
65
164
64
161
62
155
60
150

Advertisement

Table of Contents
loading

This manual is also suitable for:

G96ctn

Table of Contents